13 / 30 page ![]() 13 CJ2M-CPU3 @/-CPU1@/-MD21@ Specifications for Pulse I/O Functions The following functions of CJ2M can be used by installing one or two Pulse I/O Modules. Each module has 10 high-speed inputs and 6 high-speed outputs. Pulse I/O Modules can be installed on CJ2M CPU Units with Unit Version 2.0 or Later. • The inputs can be used as general-purpose inputs, interrupt inputs, quick-response inputs, high-speed counters, or origin search inputs. • The outputs can be used as general-purpose outputs, pulse outputs, origin search outputs, or PWM outputs. Performance Specifications Function Specifications Item Description Pulse I/O Model of Pulse I/O Modules CJ2M-MD211 (Sinking-type) CJ2M-MD212 (Sourcing-type ) External Interface 40-pin MIL connector Pulse Inputs Can be used as normal inputs, interrupt inputs, quick-response inputs, or high-speed counter inputs. (Function of each input must be selected in the PLC Setup.) Input method: Line-driver input or 24-VDC input (selected by wiring) Normal Inputs 20 max. (10 per Pulse I/O Module) Input constants: Set in the PLC Setup (0, 0.5, 1, 2, 4, 8, 16, or 32 ms). Default: 8 ms Interrupt Inputs and Quick-response Inputs 8 max. (4 per Pulse I/O Module) Input signal minimum ON pulse width: 30 μs High-speed Counter Inputs 4 max. (2 per Pulse I/O Module) Input method: Differential-phase ( ×4) pulses, pulse + direction, up/down pulses, or increment pulse Maximum response frequency: 50 kHz for differential phases or 100 kHz for single phase Counting mode: Linear mode or circular (ring) mode Count value: 32 bits Counter reset: Phase Z + software reset or software reset Control method: Target-value comparison or range comparison Gate function: Supported Pulse Outputs Can be used as normal outputs, pulse outputs, or PWM outputs. (Function of each output must be selected in the PLC Setup.) Output method: Sinking or sourcing transistor outputs (The method is determined by Pulse I/O Module model.) Normal Outputs 12 max. (6 per Pulse I/O Module) Pulse Outputs 4 max. (2 per Pulse I/O Module) Output method: CW/CCW or pulse + direction (The method is determined by the I/O wiring and the instructions used in the ladder program.) Output frequency: 1 pps to 100 kpps (in increments of 1 pps) Output Mode: Continuous mode (for speed control) or independent mode (for position control) Output pulses: Relative coordinates: 0000 0000 to 7FFF FFFF hex (0 to 2,147,483,647 pulses) Absolute coordinates: 8000 0000 to 7FFF FFFF hex ( −2,147,483,648 to 2,147,483,647) Acceleration/deceleration curves: Linear or S-curve Origin search function: Supported PWM Outputs 4 max. (2 per Pulse I/O Module) Output frequency: 0.1 to 6,553.5 Hz (in 0.1-Hz increments) or 1 to 32,800 Hz (in 1-Hz increments) Duty ratio: 0.0% to 100.0% (in 0.1% increments) Functions Description Pulse I/O Functions Pulse Input Functions Normal Inputs Input signals are read during I/O refreshing and stored in I/O memory. Interrupt Inputs An interrupt task can be started when an input signal turns ON or turns OFF. Quick-response Inputs Input signals that are shorter than the cycle time are read and stored in I/O memory. High-speed Counter Inputs High-speed pulse signals are counted. Interrupt tasks can also be started. Pulse Output Functions Normal Outputs The status of I/O memory is output during I/O refreshing. Pulse Outputs A pulse signal is output with the specified frequency and number of pulses at a fixed duty ratio (50%). PWM Outputs A pulse signal is output at the specified duty ratio. Origin Searches The origin point of the machine is determined according to the specified origin search parameters while actually outputting pulses and using the origin and origin proximity input signals as conditions. (Pulse inputs and outputs are also used for this function.) Interrupt Input Interrupt Function A task is started for an interrupt input from a Pulse I/O Module or for a high-speed counter input. Input Interrupts Interrupt tasks are executed when the interrupt input turns ON or turns OFF. Direct Mode: An interrupt task is executed each time an input signal changes. Counter Mode: Changes in the input signal are counted up or down and the interrupt task is executed when the counter counts out. (The maximum response frequency is 3 kHz.) High-speed Counter Interrupts An interrupt task is executed when preset comparison conditions for a high-speed counter are met. Target-value comparison: The interrupt task is executed when the count matches a specified value. Range comparison: The interrupt task is executed when the count enters or leaves a specified range of values. Connected Pulse I/O Module 0 Pulse I/O Module CJ2M CPU Unit (Standard or Simple Model) One Pulse I/O Module can be mounted Pulse I/O Module 1 Connected Connected Pulse I/O Module 0 Pulse I/O Module CJ2M CPU Unit (Standard or Simple Model) Note: The Pulse I/O Module closest to the CPU Unit is Pulse I/O Module 0 and the other one is Pulse I/O Module 1. Two Pulse I/O Modules can be mounted |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |