6 / 20 page ![]() 2.4 Wiring Caution: Level controls are shipped from the factory with the enclosing tube tightened and the middle set screw, on the housing base, locked to the enclosing tube. Failure to loosen the set screw prior to repositioning the conduit connection may cause the enclosing tube to loosen, resulting in the possible leakage of the process liquid or vapor. Most B40 level control switch housings are designed to allow 360° positioning of the conduit outlet by loosening the set screw(s) located under the housing base. High temperature wire must be used between control and first junction box located in a cooler area. NOTE: A switch or circuit breaker shall be installed in close proximity to equipment and within easy reach of operator. It shall be marked as the disconnecting device for equipment. 1. To gain access to switch mechanism, remove switch housing cover. 2. Pull in supply wires (conductors), wrap them around enclosing tube under the baffle plate and connect to proper terminals. Be certain that excess wire does not interfere with tilt of switch, and that adequate clearance exists for replacement of switch housing cover. NOTE: For supply connections in installations with ambient tempera- ture up to +70° C, use wire with a minimum rating of +75° C as required by process conditions. Installations with ambient temperatures up to +80° C require wire with a minimum rating of +85° C as required by process conditions. Use a minimum of 14 AWG wire for power and ground field wires. NOTE: See Figure 4 or bulletin on switch mechanism furnished for proper terminal connections. Switch bulletin numbers are listed in the chart below. 3. Connect power supply to control and test switch action by varying liquid level in float chamber. If switch mechanism fails to function, check vertical alignment of control and consult installation instructions in switch mechanism bulletin. 6 46-602 B40 Liquid Level Switches Internal Circuit (Right) Switch 1 2 3 Load Load Close on low level Common Close on high level Line 4 5 6 Internal Circuit (Left) Switch Load Load Close on low level Common Close on high level Line Figure 4 Switch Series Letter Description Bulletin No. A Standard Mercury Switch 42-683 3, L Mercury Switch w/Beaded Leads C, D, S Dry Contact Switch 2, E, L Vibration Resistant Mercury Switch F Hermetically Sealed Snap Switch HS Hermetically Sealed Snap Switch 42-694 R High Temperature Snap Switch 42-799 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |