| 数据搜索系统,热门电子元器件搜索 |
|
B40-1F30-FKB 数据表(PDF) 7 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
B40-1F30-FKB 数据表(HTML) 7 Page - Magnetrol International, Inc. |
|
7 / 20 page ![]() 4. Replace switch housing cover and place control into service. If control has been furnished with NEMA 7/9 explosion proof (cast) or NEMA 4 moisture proof (gasketed) switch housing, check the following: 1. After wiring connections have been completed, housings must be sealed at the conduit outlet with a suitable com- pound to prevent entrance of air. 2. Check cover to base fit to be certain gasketed joint is tight. A positive seal is necessary to prevent infiltration of mois- ture laden air or corrosive gases into switch housings. 3.0 Preventive Maintenance Periodic inspections are a necessary means to keep your Magnetrol level control in good working order. This control is a safety device to protect the valuable equipment it serves. A systematic program of preventive maintenance must be implemented when the control is placed into service. If the following is observed, your control will provide reliable protection of your capital equipment for many years. 3.1 What to do 3.1.1 Keep control clean Be sure the switch housing cover is always in place on the control. This cover is designed to keep dust and dirt from interfering with switch mechanism operation. In addition, it protects against damaging moisture, and acts as a safety feature by keeping bare wires and terminals from being exposed. Should the housing cover or any seals become damaged or misplaced, obtain a replacement immediately. 3.1.2 Inspect switch mechanisms, terminals, and connections monthly a. Mercury switches may be visually inspected for short circuit damage. Check for small cracks in the glass tube containing the mercury. Such cracks can allow entrance of air into the tube causing the mercury to oxidize. This is noticeable as the mercury will appear dirty or dull, and will not break into clean, round pools. If these conditions exist, replace the mercury switch immediately. b. Dry contact switches should be inspected for excessive wear on actuating lever or misalignment of adjustment screw at point of contact between screw and lever. Such wear can cause false switch actuating levels. Replace switch mecha- nism if wear or misalignment are apparent. 7 46-602 B40 Liquid Level Switches |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |