59 / 76 page ![]() Dimensions are shown in mm (inch) Dimensions subject to change 58 ZIF Connectors Tools and Assembly Assembly Instructions for Square Post Contacts Contact Insertion: Square Post Contacts are factory installed but can be removed and replaced if damaged in service. Step 1. Prior to inserting contacts, actuating handle must be in the maximum open position. Actuating handle will be facing toward connector front face, see Figure 1. Step 2. Contacts are inserted from the insulator front face by hand and are seated and clicked in the cavity by pulling on the terminal post with flat nose pliers, see Figure 2. Figure 1 Figure 2 CONNECTOR FRONT FACE CONTACT RETENTION LANCE Contact Removal for Square Post Contacts Tool: CET-ECP and CET-ECP-1 Place tool over square post terminal and impact tool. Apply sufficient force to collapse retention lance and push contact out of insulator. This process destroys the retention lance. CONTACT RETENTION LANCE |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|