| 数据搜索系统,热门电子元器件搜索 |
|
AD7607 数据表(PDF) 24 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7607 数据表(HTML) 24 Page - Analog Devices |
|
24 / 36 page ![]() AD7609 Data Sheet Rev. A | Page 24 of 36 TYPICAL CONNECTION DIAGRAM Figure 41 shows the typical connection diagram for the AD7609. There are four AVCC supply pins on the part that can be tied together and decoupled using a 100 nF capacitor at each supply pin and a 10 µF capacitor at the supply source. The AD7609 can operate with the internal reference or an externally applied reference. In this configuration, the AD7609 is config- ured to operate with the internal reference. When using a single AD7609 device on the board, the REFIN/REFOUT pin should be decoupled with a 10 µF capacitor. In an application with multiple AD7609 devices, see the Internal/External Reference section. The REFCAPA and REFCAPB pins are shorted together and decoupled with a 10 µF ceramic capacitor. The VDRIVE supply is connected to the same supply as the pro- cessor. The voltage on VDRIVE controls the voltage value of the output logic signals. For layout, decoupling, and grounding hints, see the Layout Guidelines section. After supplies are applied to the AD7609, a reset should be applied to the AD7609 to ensure that it is configured for the correct mode of operation. POWER-DOWN MODES There are two power-down modes available on the AD7609. The STBY pin controls whether the AD7609 is in normal mode or one of the two power-down modes. The two power-down modes available are standby mode and shutdown mode. The power-down mode is selected through the state of the RANGE pin when the STBY pin is low. Table 8 shows the configurations required to choose the desired power-down mode. When the AD7609 is placed in standby mode, the current consumption is 8 mA maximum and power-up time is approximately 100 µs because the capacitor on the REFCAPA/REFCAPB pins must charge up. In standby mode, the on-chip reference and regulators remain powered up and the amplifiers and ADC core are powered down. When the AD7609 is placed in shutdown mode, the current consumption is 11 µA maximum and power up time is about 13 ms. In shutdown mode, all circuitry is powered down. When the AD7609 is powered up from shutdown mode, a reset signal must be applied to the AD7609 after the required power-up time has elapsed. Table 8. Power-Down Mode Selection Power-Down Mode STBY RANGE Standby 0 1 Shutdown 0 0 AVCC AGND VDRIVE + REFIN/REFOUT DB0 TO DB15 CONVST A, B CS RD BUSY RESET AD7609 1µF 10µF 100nF DIGITAL SUPPLY VOLTAGE +2.3V TO +5V ANALOG SUPPLY VOLTAGE 5V1 EIGHT DIFFERENTIAL ANALOG INPUT PAIRS PARALLEL INTERFACE 1DECOUPLING SHOWN ON THE AVCC PIN APPLIES TO EACH AVCC PIN (PIN 1, PIN 37, PIN 38, PIN 48). DECOUPLING CAPACITOR CAN BE SHARED BETWEEN AVCC PIN 37 AND PIN 38. 2DECOUPLING SHOWN ON THE REGCAP PIN APPLIES TO EACH REGCAP PIN (PIN 36, PIN 39). REGCAP2 + 10µF REFCAPA REFCAPB OS 2 OS 1 OS 0 OVERSAMPLING 100nF V1+ PAR/SER SEL STBY REF SELECT RANGE V2+ V3+ V4+ V5+ V6+ V7+ V8+ REFGND V1– V2– V3– V4– V5– V6– V7– V8– VDRIVE VDRIVE Figure 41. Typical Connection Diagram |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |