23 / 51 page ![]() L6474 Functional description Doc ID 022529 Rev 2 23/51 Attention: The overcurrent shutdown is a critical protection feature. It is not recommended to disable it. 6.10 Undervoltage lock-out (UVLO) The L6474 provides a motor supply UVLO protection. When the motor supply voltage falls below the VSthOff threshold voltage, the STATUS register UVLO flag is forced low. When a GetStatus command is sent to the IC, and the undervoltage condition has expired, the UVLO flag is released (see paragraphs 9.1.13 and 9.2.7). Undervoltage condition expires when the motor supply voltage goes over the VSthOn threshold voltage. When the device is in undervoltage condition no motion can be performed. The UVLO flag is forced low by logic reset (power-up included) even if no UVLO condition is present. 6.11 Thermal warning and thermal shutdown An internal sensor allows the L6474 to detect when the device internal temperature exceeds a thermal warning or an overtemperature threshold. When the thermal warning threshold (Tj(WRN)) is reached, the TH_WRN bit in the STATUS register is forced low (see paragraph 9.1.13) until the temperature decreases below Tj(WRN) and a GetStatus command is sent to the IC (see paragraphs 9.1.13 and 9.2.7). When the thermal shutdown threshold (Tj(OFF)) is reached, the device goes into thermal shutdown condition: the TH_SD bit in the STATUS register is forced low, the power bridges are disabled, bridges in high impedance state and the HiZ bit in the STATUS register are raised (see paragraph 9.1.13). Thermal shutdown condition only expires when the temperature goes below the thermal warning threshold (Tj(WRN)). On exiting thermal shutdown condition, the bridges are still disabled (HiZ flag high). 6.12 Reset and standby The device can be reset and put into standby mode through a dedicated pin. When the STBY\RST pin is driven low, the bridges are left open (High Z state), the internal charge pump is stopped, the SPI interface and control logic are disabled, and the internal 3 V voltage regulator maximum output current is reduced to IREG,STBY; as a result the L6474 heavily reduces the power consumption. At the same time the register values are reset to default and all protection functions are disabled. STBY\RST input must be forced low at least for tSTBY, min. in order to ensure the complete switch to standby mode. On exiting standby mode, as well as for IC power-up, a delay of up to tlogicwu must be given before applying a new command to allow proper oscillator and logic startup and a delay of up to tcpwu must be given to allow the charge pump startup. On exiting standby mode the bridges are disabled (HiZ flag high). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |