| 数据搜索系统,热门电子元器件搜索 |
|
M41T00CAP 数据表(PDF) 16 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M41T00CAP 数据表(HTML) 16 Page - STMicroelectronics |
|
16 / 27 page ![]() Clock operation M41T00CAP 16/27 Doc ID 14557 Rev 5 for correction. Note that setting or changing the calibration byte does not affect the frequency test output frequency. The FT/OUT pin is an open drain output which requires a pull-up resistor to VCC for proper operation. A 500-10 kΩ resistor is recommended in order to control the rise time. The FT bit is cleared on power-down. Figure 10. Crystal accuracy across temperature Figure 11. Clock calibration 4.3 Century bit Bits D7 and D6 of clock register 02h contain the century enable bit (CEB) and the century bit (CB). Setting CEB to a '1' will cause CB to toggle, either from a '0' to '1' or from '1' to '0' at the turn of the century (depending upon its initial state). If CEB is set to a '0,' CB will not toggle. AI07888 –160 0 10203040506070 Frequency (ppm) Temperature °C 80 –10 –20 –30 –40 –100 –120 –140 –40 –60 –80 20 0 –20 = –0.036 ppm/ °C 2 ± 0.006 ppm/°C2 K ΔF = K x (T – T O) 2 F T O = 25°C ± 5°C AI00594B NORMAL POSITIVE CALIBRATION NEGATIVE CALIBRATION |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|