| 数据搜索系统,热门电子元器件搜索 |
|
MAS6512 数据表(PDF) 6 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS6512 数据表(HTML) 6 Page - Micro Analog systems |
|
6 / 12 page ![]() DA6512.000 11 July, 2012 6 (26) OPERATING MODES MAS6512 has two capacitance measurement modes and one temperature measurement mode. In capacitance measurement mode the output is proportional to either capacitance difference (CS-CR) or to capacitance ratio (CS-CR)/CS. In temperature measurement mode the output is proportional to the absolute temperature. Measurement mode configuration and start of conversion is done by writing 8-bit configuration data to the Measurement control register (address E2HEX). See further details in the Measurement control register chapter. MAS6512 includes a 256-bit EEPROM memory for storing trim and calibration data on chip. Four bytes (32 bits) of EEPROM are reserved for trim values but the remaining 28 bytes (224 bits) are free for calibration and other data. The stored trim data consists of measurement configuration settings that are automatically read from EEPROM memory in the beginning of each conversion. The calibration data should comprise of calibration and temperature compensation coefficients that can be used to calculate accurate calibrated sensor and temperature measurement results from the non- calibrated measurement reading. All calculations need to be done in an external micro controller unit (MCU). A calibrated MAS6512 sensor system should be operated as illustrated in figure 2. The calibration and compensation coefficients need to be read to the MCU memory only once. From each pair of sensor and temperature measurement readings the accurate sensor and temperature values can then be calculated by using an external MCU. All communication with MAS6512 is done using either the I 2C ® bus or the SPI bus. Starting an A/D conversion, reading the conversion result and reading and writing data from and to the EEPROM memory are all accomplished via serial bus communication. In addition to the serial buses the digital interface includes also end-of-conversion (EOC) and master reset (XCLR) pins. See A/D Conversion in the Serial Data Interface (I 2C ® Bus) Control chapter. Figure 2. Flow chart for a calibrated MAS6512 sensor system START READ EEPROM CALIBRATION DATA MEASURE SENSOR MEASURE TEMPERATURE CALCULATE CALIBRATED TEMPERATURE CALCULATE TEMPERATURE COMPENSATED SENSOR VALUE |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |