PCF8523T 数据表(PDF) 45 Page - NXP Semiconductors

部件名 PCF8523T
功能描述  Real-Time Clock (RTC) and calendar
PDF  75 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  NXP [NXP Semiconductors]
网页  http://www.nxp.com
标志 NXP - NXP Semiconductors

PCF8523T 数据表(HTML) 45 Page - NXP Semiconductors

Back Button PCF8523T Datasheet HTML 41Page - NXP Semiconductors PCF8523T Datasheet HTML 42Page - NXP Semiconductors PCF8523T Datasheet HTML 43Page - NXP Semiconductors PCF8523T Datasheet HTML 44Page - NXP Semiconductors PCF8523T Datasheet HTML 45Page - NXP Semiconductors PCF8523T Datasheet HTML 46Page - NXP Semiconductors PCF8523T Datasheet HTML 47Page - NXP Semiconductors PCF8523T Datasheet HTML 48Page - NXP Semiconductors PCF8523T Datasheet HTML 49Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 45 / 75 page
background image
PCF8523
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2012. All rights reserved.
Product data sheet
Rev. 4 — 5 July 2012
45 of 74
NXP Semiconductors
PCF8523
Real-Time Clock (RTC) and calendar
8.11 I2C-bus interface
The I2C-bus is for bidirectional, two-line communication between different ICs or modules.
The two lines are a Serial DAta line (SDA) and a Serial CLock line (SCL). Both lines are
connected to a positive supply via a pull-up resistor. Data transfer is initiated only when
the bus is not busy.
8.11.1 Bit transfer
One data bit is transferred during each clock pulse. The data on the SDA line remains
stable during the HIGH period of the clock pulse as changes in the data line at this time
are interpreted as control signals (see Figure 28).
8.11.2 START and STOP conditions
Both data and clock lines remain HIGH when the bus is not busy. A HIGH-to-LOW
transition of the data line, while the clock is HIGH, is defined as the START condition (S).
A LOW-to-HIGH transition of the data line, while the clock is HIGH, is defined as the
STOP condition (P) (see Figure 29).
For this device, a repeated START is not allowed. Therefore, a STOP has to be released
before the next START.
8.11.3 System configuration
A device generating a message is a transmitter; a device receiving a message is the
receiver. The device that controls the message is the master and the devices, which are
controlled by the master, are the slaves.
Fig 28. Bit transfer
mbc621
data line
stable;
data valid
change
of data
allowed
SDA
SCL
Fig 29. Definition of START and STOP conditions
mbc622
SDA
SCL
P
STOP condition
SDA
SCL
S
START condition



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com