12 / 15 page ![]() DAC8222 –12– REV. C Figure 26. Single Supply Operation (Current Switching Mode) SINGLE SUPPLY OPERATION CURRENT STEERING MODE Because the DAC8222’s R-2R resistor ladder terminating resis- tor is internally connected to AGND, it lends itself well to single supply operation in the current steering mode. This means that AGND can be raised above system ground as shown in Figure 26. The output voltage range will be from +5 V to +10 V depending on the digital input code and is given by: VOUT = VOS + (n/4096) (VOS) where VOS = Offset Reference Voltage (+5 V in Figure 26) where n = Decimal Equivalent of the Digital Input Word VOLTAGE SWITCHING MODE Figure 27 shows the DAC8222 in a single supply voltage switching mode of operation. In this configuration, the DAC’s R-2R ladder acts as a voltage divider. The output voltage at the VREF pin exhibits a constant impedance R (typically 11 k Ω) and must be buffered by an op amp. RFB pins are not used in this circuit configuration. The reference input voltage must be main- tained within +1.25 V of AGND and VDD from +12 V to +15 V to preserve device accuracy. The output voltage expression is given by: VOUT = VREF (n/4096) where n = Decimal Equivalent of the Digital Input Word APPLICATIONS TIPS GENERAL GROUND MANAGEMENT Grounding techniques should be tailored to each individual sys- tem. Ground loops should be avoided, and ground current paths should be as short as possible and have a low impedance. The DAC8222’s AGND and DGND pins should be tied to- gether at the device socket to prevent digital transients from ap- pearing at the analog output. This common point then becomes the single ground point connection. AGND and DGND should then be brought out separately and tied to their respective power supply grounds. Ground loops can be created if both grounds are tied together at more than one location, i.e., tied together at the device and at the digital and analog power supplies. A PC board ground plane can be used for the single point ground connection should the connections not be practical at the device socket. If neither of these connections is practical or allowed, the device should be placed as close as possible to the system’s single point ground connection. Back-to-back Schottky diodes should then be connected between AGND and DGND. POWER SUPPLY DECOUPLING Power supplies used with the DAC8222 should be well filtered and regulated. Local supply decoupling consisting of a 1 µF to 10 µF tantalum capacitor in parallel with a 0.1 µF ceramic is highly recommended. The capacitors should be connected be- tween the VDD and DGND pins and at the device socket. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |