| 数据搜索系统,热门电子元器件搜索 |
|
CS1W-RPT02 数据表(PDF) 27 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
CS1W-RPT02 数据表(HTML) 27 Page - Omron Electronics LLC |
|
27 / 70 page ![]() Programmable Controllers SYSMAC CS1G/H 15 Current Consumption for Power Supply Units ■ Checking Current Consumption and Power Consumption After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for each Rack. Condition 1: Current Requirements There are three voltage groups for internal power consumption: 5 V, 26 V, and 24 V. • Current consumption at 5 V (internal logic power supply) • Current consumption at 26 V (relay driving power supply) • Current consumption at 24 V (power supply output terminals) (C200HW-PA204S only) Condition 2: Power Requirements For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current supplied for the voltage groups shown in the following tables. ● CPU Racks and Expansion Racks The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are shown below. Note 1:For CPU Racks, include the CPU Backplane and CPU Unit current and power consumption in the calculations. 2: For Expansion Racks, include the Expansion Backplanes current and power consumption in the calculations. Conditions 1 and 2 below must be satisfied. Condition 1: Maximum Current (1) Total Unit current consumption at 5 V ≤ (A) value (2) Total Unit current consumption at 26 V ≤ (B) value (3) Current consumption for service power supply at 24 V ≤ (C) value (Only when using the service power supply from the C200HW-PA204S.) Condition 2: Maximum Power (1) x 5 V + (2) x 26 V + (3) x 24 V ≤ (D) value ■ Example: Calculating Total Current and Power Consumption Example: When the Following Units are Mounted to a CS-series CPU Rack Using a CS1W-PA204S Power Supply Unit Note: For details on Unit current consumption, refer to Ordering Information. Power Supply Units Max. current supplied (D) Max. total power supplied (A) 5 V (B) 26 V (C) 24 V C200HW-PA204C 4.6 A 0.6 A --- 30 W C200HW-PA204 4.6 A 0.6 A --- 30 W C200HW-PA204S 4.6 A 0.6 A 0.8 A 30 W C200HW-PA204R 4.6 A 0.6 A --- 30 W C200HW-PA209R 9 A 1.3 A --- 45 W C200HW-PD024 4.6 A 0.6 A --- 30 W C200HW-PD025 5.3 A 1.3 A --- 40 W CS1D-PA207R 7 A 1.3 A --- 35 W CS1D-PD024 4.3 A 0.56 A --- 28 W Type Model Quantity Voltage group 5 V 26 V 24 V CPU Backplanes (8 slots) CS1W-BC083 1 0.11 A --- --- CPU Unit CS1H-CPU67H 1 0.82 A --- --- Input Unit CS1W-ID211 2 0.10 A --- --- CS1W-ID291 2 0.20 A --- --- Output Unit CS1W-OC201 2 0.10 A 0.048 A --- Special I/O Unit CS1W-NC213 1 0.25 A --- --- CPU Bus Unit CS1W-CLK23 1 0.33 A --- --- Service power supply 0.3 A used --- --- 0.3 A Current consumption Total 0.11 A + 0.82 A + 0.10 A x 2 + 0.20 A x 2 + 0.10 A x 2 + 0.25 A + 0.33 A 0.048 A x 2 0.3 A Result 2.31 A ( ≤ 4.6 A) 0.096 A ( ≤ 0.6 A) 0.3 A ( ≤ 0.8 A) Power consumption Total 2.31 A x 5 V=11.55 W 0.096 A x 26 V=2.496 W 0.3 A x 24 V=7.2 W Result 11.55 + 2.496 + 7.2 = 21.246W ( ≤ 30W) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |