| 数据搜索系统,热门电子元器件搜索 |
|
ADP1755ACPZ-R7 数据表(PDF) 15 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1755ACPZ-R7 数据表(HTML) 15 Page - Analog Devices |
|
15 / 20 page ![]() Data Sheet ADP1754/ADP1755 Rev. E | Page 15 of 20 In this example, the worst-case temperature coefficient (TEMPCO) over −40°C to +85°C is assumed to be 15% for an X5R dielectric. The tolerance of the capacitor (TOL) is assumed to be 10%, and COUT = 4.46 μF at 1.8 V, as shown in Figure 35. Substituting these values in Equation 3 yields CEFF = 4.46 μF × (1 − 0.15) × (1 − 0.1) = 3.41 μF Therefore, the capacitor chosen in this example meets the minimum capacitance requirement of the LDO over temper- ature and tolerance at the chosen output voltage. To guarantee the performance of the ADP1754/ADP1755, it is imperative that the effects of dc bias, temperature, and toler- ances on the behavior of the capacitors be evaluated for each application. UNDERVOLTAGE LOCKOUT The ADP1754/ADP1755 have an internal undervoltage lockout circuit that disables all inputs and the output when the input voltage is less than approximately 1.58 V. This ensures that the ADP1755/ADP1755 inputs and the output behave in a predicta- ble manner during power-up. CURRENT-LIMIT AND THERMAL OVERLOAD PROTECTION The ADP1754/ADP1755 are protected against damage due to excessive power dissipation by current-limit and thermal overload protection circuits. The ADP1754/ADP1755 are designed to reach current limit when the output load reaches 2 A (typical). When the output load exceeds 2 A, the output voltage is reduced to maintain a constant current limit. Thermal overload protection is included, which limits the junction temperature to a maximum of 150°C (typical). Under extreme conditions (that is, high ambient temperature and power dissipation) when the junction temperature begins to rise above 150°C, the output is turned off, reducing the output current to zero. When the junction temperature drops below 135°C (typical), the output is turned on again and the output current is restored to its nominal value. Consider the case where a hard short from VOUT to ground occurs. At first, the ADP1754/ADP1755 reach current limit so that only 2 A is conducted into the short. If self-heating of the junction becomes great enough to cause its temperature to rise above 150°C, thermal shutdown activates, turning off the output and reducing the output current to zero. As the junction temperature cools and drops below 135°C, the output turns on and conducts 2 A into the short, again causing the junction temperature to rise above 150°C. This thermal oscillation between 135°C and 150°C causes a current oscillation between 2A and 0 A that continues as long as the short remains at the output. Current-limit and thermal overload protections are intended to protect the device against accidental overload conditions. For reliable operation, device power dissipation should be externally limited so that junction temperatures do not exceed 125°C. THERMAL CONSIDERATIONS To guarantee reliable operation, the junction temperature of the ADP1754/ADP1755 must not exceed 125°C. To ensure that the junction temperature stays below this maximum value, the user needs to be aware of the parameters that contribute to junction temperature changes. These parameters include ambient temp- erature, power dissipation in the power device, and thermal resistance between the junction and ambient air (θJA). The θJA value is dependent on the package assembly compounds used and the amount of copper to which the GND pin and the exposed pad (EPAD) of the package are soldered on the PCB. Table 6 shows typical θJA values for the 16-lead LFCSP for various PCB copper sizes. Table 7 shows typical ΨJB values for the 16-lead LFCSP. Table 6. Typical θJA Values Copper Size (mm2) θJA (°C/W), LFCSP 01 130 100 80 500 69 1000 54 6400 42 1 Device soldered to minimum size pin traces. Table 7. Typical ΨJB Values Copper Size (mm2) ΨJB (°C/W) @ 1 W 100 32.7 500 31.5 1000 25.5 The junction temperature of the ADP1754/ADP1755 can be calculated from the following equation: TJ = TA + (PD × θJA) (4) where: TA is the ambient temperature. PD is the power dissipation in the die, given by PD = [(VIN − VOUT) × ILOAD] + (VIN × IGND) (5) where: VIN and VOUT are the input and output voltages, respectively. ILOAD is the load current. IGND is the ground current. Power dissipation due to ground current is quite small and can be ignored. Therefore, the junction temperature equation can be simplified as follows: TJ = TA + {[(VIN − VOUT) × ILOAD] × θJA} (6) As shown in Equation 6, for a given ambient temperature, input- to-output voltage differential, and continuous load current, a minimum copper size requirement exists for the PCB to ensure that the junction temperature does not rise above 125°C. Figure 36 through Figure 41 show junction temperature calculations for different ambient temperatures, load currents, VIN to VOUT differentials, and areas of PCB copper. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |