| 数据搜索系统,热门电子元器件搜索 |
|
AD9920ABBCZ 数据表(PDF) 49 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9920ABBCZ 数据表(HTML) 49 Page - Analog Devices |
|
49 / 112 page ![]() AD9920A Rev. B | Page 49 of 112 Mode Registers The mode registers are used to select the field timing of the AD9920A. Typically, all of the field, V-sequence, and V-pattern information is programmed into the AD9920A at startup. During operation, the mode registers allow the user to select any combi- nation of field timing to meet the requirements of the system. The advantage of using the mode registers in conjunction with preprogrammed timing is that it greatly reduces the system pro- gramming requirements during camera operation. Only a few register writes are required when the camera operating mode is changed; the vertical timing information does not need to be changed with each camera mode change. A basic still camera application can require six fields of vertical timing—one for draft mode operation, one for autofocusing, and four for still image readout. All of the register timing informa- tion for the six fields is loaded at startup. Then, during camera operation, the mode registers select which field timing is active, depending on how the camera is being used. Table 22 shows how the mode registers are used. The mode register (Address 0x2A) specifies how many total fields are used. Any value from 1 to 7 can be selected using these three bits. The other two registers (Address 0x2B and Address 0x2C) are used to select which of the programmed fields are used and in which order. Up to seven fields can be used in a single write to the mode register. The AD9920A starts with the field timing specified by FIELD1, and on the next VD switches to the timing specified by FIELD2, and so on. After completing the total number of fields specified by the mode register, the AD9920A repeats by starting at the first field. This continues until a new write to the mode register occurs. Figure 61 shows example mode register settings for different field configurations. Note that only a write to Address 0x2C properly resets the field counter. Therefore, when changing the values in any of the mode registers, it is recommended that all three registers be updated together in the same field (VD period). Caution The mode registers are SCK updated by default. If they are configured as VD-updated registers by writing Address 0xB4 = 0x03FF and Address 0xB5 = 0xFC00, the new mode informa- tion is updated on the second VD falling edge after the write occurs, rather than on the first VD falling edge. See Figure 63 for an example. Table 22. Mode Registers Address Name Length (Bits) Description 0x2A MODE 3 Total number of fields to cycle through. Set from 1 to 7. 0x2B FIELD1 5 Selected field (from FIELD registers in configurable memory) for the first field to cycle through. FIELD2 5 Selected field (from FIELD registers in configurable memory) for the second field to cycle through. FIELD3 5 Selected field (from FIELD registers in configurable memory) for the third field to cycle through. FIELD4 5 Selected field (from FIELD registers in configurable memory) for the fourth field to cycle through. FIELD5 5 Selected field (from FIELD registers in configurable memory) for the fifth field to cycle through. 0x2C FIELD6 5 Selected field (from FIELD registers in configurable memory) for the sixth field to cycle through. FIELD7 5 Selected field (from FIELD registers in configurable memory) for the seventh field to cycle through. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |