64 / 112 page ![]() AD9920A Rev. B | Page 64 of 112 GENERAL-PURPOSE OUTPUTS (GPOs) The AD9920A provides programmable outputs to control a mechanical shutter, the strobe/flash, the CCD bias select signal, or any other external component with general-purpose (GP) signals. Eight GP signals, with up to four toggles each, are available to be programmed and assigned to special GPO pins. These pins are bidirectional and allow visibility (as an output) and external control (as an input) of HBLK, PBLK, CLPOB, and OUT_CONTROL. The GPO registers are described in Table 45. Note that GPO5 and GPO6 are used to control the SG signals for the V5 and V6 outputs of the AD9920A. See the SG Control Using GPO section for more information. GP Toggles When configured as an output, each GPO output can deliver a signal that is the result of programmable toggle positions. The GP signals are independent and can be linked to a specific VD period or to a range of VD periods via the primary or secondary field counters through the GP protocol register (Address 0x73). As a result of their associations with the field counters, the GP toggles inherit the characteristics of the field counters, such as RapidShot and ShotTimer. To program the GP toggles, complete the following steps: 1. Program the toggle positions (Address 0x7C to Address 0xAB). 2. Program the GP protocol (Address 0x73). 3. Program the counter parameters (Address 0x71 to Address 0x72). 4. Activate the counter (Address 0x70). For Protocol 1 (no counter association), skip Step 3 and Step 4. With these four steps, the GP signals can be programmed to accomplish many common tasks. Careful protocol selection and application of the field counters yields efficient results to allow the GP signals smooth integration with concurrent operations. Note that the SUBCK and VSG masks are linked to the primary counter; however, if their parameters are 0, the GPO can use the primary counter without expose/read activity. The secondary counter is independent and can be used simul- taneously with the primary counter. Some applications may require the use of both primary and secondary field counters with different GPO protocols, start times, and durations. Such operations are easily handled by the AD9920A. Several simple examples of GPO applications using only one GPO and one field counter follow. These examples can be used as building blocks for more complex GPO activity. In addition, specific GPO signals can be passed through a four-input lookup table (LUT) to realize combinational logic between them. For example, GP1 and GP2 can be sent through an XOR lookup table, and the result can be delivered on GP1, GP2, or both. In addition, GP1 or GP2 can deliver its original toggles. Table 45. GPO Registers Register Length (Bits) Range Description GP1_PROTOCOL 3 0 to 7 0 = idle GP2_PROTOCOL 3 0 to 7 1 = no counter association; use MANUAL_TRIG bits to enable each GP signal. GP3_PROTOCOL 3 0 to 7 2 = test only. GP4_PROTOCOL 3 0 to 7 3 = test only. GP5_PROTOCOL 3 0 to 7 4 = link to mode counter (from vertical timing generation). GP6_PROTOCOL 3 0 to 7 5 = link to primary counter (also allows GP signals to repeat with RapidShot). GP7_PROTOCOL 3 0 to 7 6 = link to secondary counter (also allows GP signals to repeat with RapidShot). GP8_PROTOCOL 3 0 to 7 7 = keep on. MANUAL_TRIG 8 On/off Manual trigger for each GP signal. For use with Protocol 1. GP[1:8]_POL 8 Low/high Starting polarity for GP signals. Only updated when GPx_PROTOCOL = 0. SEL_GP[1:8] 8 On/off 1 = select GP toggles visible at GPO1 to GPO4, GPO7, and GPO8 when output is enabled (default). 0 = select vertical signals visible at GPO4 to GPO8 when output is enabled. GPO4: XSUBCK. GPO5: XV21. GPO6: XV22. GPO7: XV23. GPO8: XV24. GPO_OUTPUT_EN 8 On/off 1 = enable GPO1 to GPO4, GPO7, and GPO8 outputs (one bit per output). 0 = disable GPO1 to GPO4, GPO7, and GPO8 outputs; pins are high-Z (default). GPx_USE_LUT 8 On/off Send GP signals through a programmable lookup table (LUT). LUT_FOR_GP12 4 Logic setting Desired logic to be realized on GPO1 combined with GPO2. LUT_FOR_GP34 4 Logic setting Desired logic to be realized on GPO3 combined with GPO4. LUT_FOR_GP56 4 Logic setting Desired logic to be realized on GPO5 combined with GPO6. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |