35 / 127 page ![]() P R E L I M I N A R Y AMD 1-377 Am79C960 A typical receive poll occurs under the following conditions: 1) PCnet-ISA controller does not possess ownership of the current RDTE and the poll time has elapsed and RXON = 1, or 2) PCnet-ISA controller does not possess ownership of the next RDTE and the poll time has elapsed and RXON = 1. If RXON = 0, the PCnet-ISA controller will never poll RDTE locations. If RXON=1, the system should always have at least one RDTE available for the possibility of a receive event. When there is only one RDTE, there is no polling for next RDTE. A typical transmit poll occurs under the following conditions: 1) PCnet-ISA controller does not possess ownership of the current TDTE and DPOLL = 0 and TXON = 1 and the poll time has elapsed, or 2) PCnet-ISA controller does not possess ownership of the current TDTE and DPOLL = 0 and TXON = 1 and a packet has just been received, or 3) PCnet-ISA controller does not possess ownership of the current TDTE and DPOLL = 0 and TXON = 1 and a packet has just been transmitted. The poll time interval is nominally defined as 32,768 crystal clock periods, or 1.6 ms. However, the poll time register is controlled internally by microcode, so any other microcode controlled operation will interrupt the incrementing of the poll count register. For example, when a receive packet is accepted by the PCnet-ISA controller, the device suspends execution of the poll- time-incrementing microcode so that a receive microcode routine may instead be executed. Poll-time- incrementing code is resumed when the receive operation has completely finished. Note, however, that following the completion of any receive or transmit op- eration, a poll operation will always be performed. The poll time count register is never reset. Note that if a non- default value is desired, then a strict sequence of setting the INIT bit in CSR0, waiting for INITDONE, then writing to CSR47, and then setting STRT in CSR0 must be ob- served, otherwise the default value will not be overwritten. See the CSR47 section for details. Setting the TDMD bit of CSR0 will cause the microcode controller to exit the poll counting code and immediately perform a polling operation. If RDTE ownership has not been previously established, then an RDTE poll will be performed ahead of the TDTE poll. Transmit Descriptor Table Entry (TDTE) If, after a TDTE access, the PCnet-ISA controller finds that the OWN bit of that TDTE is not set, then the PCnet-ISA controller resumes the poll time count and reexamines the same TDTE at the next expiration of the poll time count. If the OWN bit of the TDTE is set, but STP = 0, the PCnet-ISA controller will immediately request the bus in order to reset the OWN bit of this descriptor; this condi- tion would normally be found following a LCOL or RETRY error that occurred in the middle of a transmit packet chain of buffers. After resetting the OWN bit of this descriptor, the PCnet-ISA controller will again im- mediately request the bus in order to access the next TDTE location in the ring. If the OWN bit is set and the buffer length is 0, the OWN bit will be reset. In the LANCE the buffer length of 0 is interpreted as a 4096-byte buffer. It is acceptable to have a 0 length buffer on transmit with STP = 1 or STP = 1 and ENP = 1. It is not acceptable to have 0 length buffer with STP = 0 and ENP = 1. If the OWN bit is set and the start of packet (STP) bit is set, then microcode control proceeds to a routine that will enable transmit data transfers to the FIFO. If the transmit buffers are data chained (ENP=0 in the first buffer), then the PCnet-ISA controller will look ahead to the next transmit descriptor after it has per- formed at least one transmit data transfer from the first buffer. More than one transmit data transfer may possi- bly take place, depending upon the state of the transmitter. The transmit descriptor lookahead reads TMD0 first and TMD1 second. The contents of TMD0 and TMD1 will be stored in Next TX Descriptor Address (CSR32), Next TX Byte Count (CSR66) and Next TX Status (CSR67) regardless of the state of the OWN bit. This transmit descriptor lookahead operation is per- formed only once. If the PCnet-ISA controller does not own the next TDTE (i.e. the second TDTE for this packet), then it will com- plete transmission of the current buffer and then update the status of the current (first) TDTE with the BUFF and UFLO bits being set. This will cause the transmitter to be disabled (CSR0, TXON = 0). The PCnet-ISA controller will have to be restarted to restore the transmit function. The situation that matches this description implies that the system has not been able to stay ahead of the PCnet-ISA controller in the transmit descriptor ring and, therefore, the condition is treated as a fatal error. To avoid this situation, the system should always set the transmit chain descriptor own bits in reverse order. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |