13 / 24 page ![]() AD5171 Rev. D | Page 13 of 24 VARIABLE RESISTANCE AND VOLTAGE FOR RHEOSTAT MODE If only the W-to-B or W-to-A terminals are used as variable resistors, the unused terminal can be opened or shorted with Terminal W. This operation is called rheostat mode (see Figure 26). A W B A W B A W B Figure 26. Rheostat Mode Configuration The nominal resistance (RAB) of the RDAC has 64 contact points accessed by the wiper terminal, plus Terminal B contact if RWB is considered. The 6-bit data in the RDAC latch is decoded to select one of the 64 settings. Assuming that a 10 kΩ part is used, the first connection of the wiper starts at Terminal B for Data 0x00. Such a connection yields a minimum of 60 Ω resistance between Terminal W and Terminal B due to the 60 Ω wiper contact resistance. The second connection is the first tap point, which corresponds to 219 Ω (RWB = 1 × RAB/63 + RW) for Data 0x01, and so on. Each LSB data value increase moves the wiper up the resistor ladder until the last tap point is reached at 10,060 Ω (63 × RAB/63 + RW). Figure 27 shows a simplified diagram of the equivalent RDAC circuit. The general equation determining RWB is W AB WB R R D D R + × = 63 ) ( (1) where: D is the decimal equivalent of the 6-bit binary code. RAB is the end-to-end resistance. RW is the wiper resistance contributed by the on-resistance of the internal switch. Table 6. RWB vs. Codes: RAB = 10 kΩ; Terminal A Open D (Dec) RWB (Ω) Output State 63 10060 Full-scale (RAB + RW) 32 5139 Midscale 1 219 1 LSB 0 60 Zero-scale (wiper contact resistance) Because a finite wiper resistance of 60 Ω is present in the zero- scale condition, care should be taken to limit the current flow between Terminal W and Terminal B in this state to a maximum pulse current 20 mA. Otherwise, degradation or possible destruction of the internal switch contact can occur. Similar to the mechanical potentiometer, the resistance of the RDAC between the wiper (Terminal W) and Terminal A also produces a complementary resistance, RWA. When these terminals are used, Terminal B can be opened or shorted to Terminal W. Setting the resistance value for RWA starts at a maximum value of resistance and decreases as the data loaded in the latch increases in value. The general equation for this operation is W AB WA R R D D R + × − = 63 63 ) ( (2) Table 7. RWA vs. Codes: RAB = 10 kΩ; Terminal B Open D (Dec) RWA (Ω) Output State 63 60 Full-scale 32 4980 Midscale 1 9901 1 LSB 0 10060 Zero-scale The typical distribution of the resistance tolerance from device to device is process-lot dependent; it is possible to have ±30% tolerance. RS RS RS A W B D5 D4 D3 D2 D1 D0 RDAC LATCH AND DECODER Figure 27. AD5171 Equivalent RDAC Circuit VARIABLE RESISTANCE AND VOLTAGE FOR POTENTIOMETER MODE If all three terminals are used, the operation is called the potentiometer mode. The most common configuration is the voltage divider operation (see Figure 28). A W B VI VO Figure 28. Potentiometer Mode Configuration |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |