25 / 34 page ![]() L9733 Fault operation Doc ID 11319 Rev 11 25/34 7 Fault operation The fault diagnostic capability consists of one internal 16 bits shift register and 2 bits are used for each output. The diagnostic information are: no fault present, overcurrent, open load and short circuit. For L9733XP all of the faults will be cleared on the rising edge of chip select if a valid DI byte was received. For L9733CN The OVC register will be cleared after the end of the diagnosis restart time Tres or by the input signal (IN) in low state. The other faults will be cleared on the rising edge of chip select if a valid DI byte was received. If all the bits b0-b15 of the fault register have value '1' it means that a thermal fault, at least on one of the eight independent Outputs, occurred. 7.1 Low-side configured output fault operation The diagnostic circuitry verifies for the low-side configured output the following condition: Normal operation, open load, short circuit to GND and overcurrent (only if the switching OFF protection, selectable for each channel via SPI bus, is active). The diagnostic circuitry operates in two different modes, selected for each channel by SPI: no latch mode and latch mode. The fault priority is overcurrent and then open load or short circuit to GND, this means that if an overcurrent occurs the fault register is always overwritten and following open load or short to GND faults that happen before that the register is cleared will be ignored. 7.1.1 No latch mode This diagnostic operating mode doesn't latch open load and short to GND faults. 1. Open load The diagnostic of open load is detected only in OFF condition sensing the Drn1-8 output voltage. This fault is detected on the falling edge of the CS input if the power Table 11. Fault register definition OUT 8 OUT 7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 MSB LSB D1 D0 D1 D0 D1 D0 D1 D0 D1 D0 D1 D0 D1 D0 D1 D0 b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 Table 12. Fault logic definition D1 D0 Fault status 0 0 No fault is present 0 1 Open load 1 0 Short circuit to GND (low-side) or short circuit to Vbat (high-side) 1 1 Overcurrent |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |