7 / 13 page ![]() DocID13304 Rev 4 7/13 ACST2 Application information 13 Figure 17. Overvoltage ruggedness test circuit for resistive and inductive loads for IEC 61000-4-5 standards Figure 18. Typical current and voltage waveforms across the ACST2 during IEC 61000-4-5 standard test 2.3 Electrical noise immunity The ACST2 is a sensitive device (IGT = 10 mA) and can be controlled directly though a simple resistor by a logic level circuit, and still provides a high electrical noise immunity. The intrinsic immunity of the ACST2 is shown by the specified dV/dt equal to 500 V/µs @ 125 °C. This immunity level is 5 to 10 times higher than the immunity provided by an equivalent standard technology Triac with the same sensitivity. In other words, the ACST2 is sensitive, but has an immunity usually available only for non-sensitive device (IGT higher than 35 mA). AC Mains R Filtering unit Rg Model of the load Rgene Surge generator ACST210-8x 2kV surge L R = 20 , L = 10 µH, VPP = 2 kV Ω I V 0 0 V peak =V CL 1.2/50 µs voltage surge 8/20 µs current surge |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|