| 数据搜索系统,热门电子元器件搜索 |
|
ACT413 数据表(PDF) 8 Page - Active-Semi, Inc |
|
|
|||||||||||||||||||||||||||||
ACT413 数据表(HTML) 8 Page - Active-Semi, Inc |
|
8 / 16 page ![]() ACT413 Rev 2, 27-Feb-14 Innovative PowerTM - 8 - www.active-semi.com Copyright © 2014 Active-Semi, Inc. Active-Semi Proprietary―For Authorized Recipients and Customers ActivePSR TM is a trademark of Active-Semi. current limit compensation circuit to achieve constant OLP over wide line and wide load range. Output Cable Resistance Compensation The ACT413 provides internal programmable output cable resistance compensation during constant voltage regulation, monotonically adding an output voltage correction up to predetermined percentage at full power. The feature allows better output voltage accuracy by compensating for the output voltage drop due to the output cable resistance. Frequency Fold-back When the load drops to 75% of full load level, ACT413 starts to decrease the switching frequency, which is proportional to the load current ,to improve the efficiency of the converter as show in Functional Block Diagram. This enables the application to meet all latest green energy standards. The actual minimum switching frequency is programmable with a small dummy load (while still meeting standby power). Valley Switching ACT413 employed valley switching from medium load to heavy load to reduce switching loss and EMI. After the switch is turned off, the ringing voltage from the auxiliary winding is applied to the VFB pin through feedback network R5, R6. Internally, the VFB pin is connected to an zero- crossing detector to generate the switch turn on signal when the conditions are met. In light load, the frequency fold back scheme starts to take control to determine the switch turn on signal, so thus the switching frequency. Figure 1: Valley Switching at heavy load Protection Features The ACT413 provides full protection functions. The following table summarizes all protection functions. Auto-Restart Operation ACT413 will enter auto-restart mode when a fault is identified. There is a startup phase in the auto- restart mode. After this startup phase the conditions are checked whether the failure is still present. Normal operation proceeds once the failure mode is removed. Otherwise, new startup phase will be initiated again. To reduce the power loss during fault mode, the startup delay control is implemented. The startup delay time increases over lines. Over Load Protection (OLP) When the secondary output current reaches a level set by the internal current limiting circuit, the ACT413 enters current limit condition and causes the secondary output voltage to drop, the IC enters fault mode and enter auto restart mode. ACT413 is able to achieve very accurate OLP (constant IOUT) independent of input lines and primary inductor values. Short Circuit Protection When the secondary side output is short circuited, the ACT413 enters hiccup mode operation. This hiccup behavior continues until the short circuit is removed. FUNCTIONAL DESCRIPTION CONT’D Vdrain_gndMosfet t DCvoltage T Ton Possible Valley turn on PROTECTION FUNCTIONS FAILURE CONDITION PROTECTION MODE VDD Over Voltage VDD > 20.5V (4 duty cycle) Auto Restart Over Temperature T > 135˚C Auto Restart Short Winding/ Short Diode VCS > 1.75V Auto Restart Over Load IPK = ILIMIT Auto Restart Output Short Circuit VFB < 0.56V Auto Restart Open Loop No switching for 4 cycle Auto Restart VCC Under Voltage VCC < 6.8V Auto Restart VFB Over Voltage VFB > 3V (4 duty cycle) Auto Restart |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |