| 数据搜索系统,热门电子元器件搜索 |
|
AN3203 数据表(PDF) 16 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3203 数据表(HTML) 16 Page - STMicroelectronics |
|
16 / 49 page ![]() Asymmetrical half bridge operation AN3203 16/49 Doc ID 17402 Rev 2 2.2 Short-circuit protection In case of a short-circuit at the AHB output the overload protection (OLP) is activated. Figure 10 shows the pins involved in this function. When the short-circuit is applied, the COMP pin saturates high. The IC detects this condition and starts charging the SS capacitor. When the SS voltage reaches 5 V the system is shut down, when it reaches 6.4 V the IC is latched. The PFC controller is also stopped: when the L6591 activates the protection, the PFC_STOP signal pulls the L6563S RUN pin down to below the 0.8V threshold. The latch is kept thanks to the auxiliary stage that remains active and provides the VCC voltage. In order to restart the system it is necessary to recycle the L6591 VCC voltage between the UVLO thresholds. This can be done by removing the PS_ON signal in the auxiliary stage. Figure 10. Short-circuit behavior detail Ch1: SS pin voltage (yellow) Ch2: COMP pin voltage (blue) Ch3: FGND pin voltage, (purple) Ch4: L6563S RUN pin voltage (green) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|