| 数据搜索系统,热门电子元器件搜索 |
|
AN4121 数据表(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN4121 数据表(HTML) 13 Page - STMicroelectronics |
|
13 / 26 page ![]() AN4121 Experimental results Doc ID 023243 Rev 1 13/26 4 Experimental results The tests have been conducted on a three-phase metering demonstration board with the STPMC1 and three STPMS2Ls considering INOM = 5 A, VNOM = 230 V, fline = 50 Hz. Results are referred to the full scale dynamic range of the current channel (“FS” in Table 7), which for the sensor selected was ± 37.5%, or as percentage of INOM. 4.1 Three-phase energy measurement accuracy 4.1.1 Test with symmetrical voltages and balanced load at PF = 1 This three-phase energy measurement has been performed in the following conditions: VR = VS = VT = 230 [VRMS] IR = IS = IT = I [ARMS] PF = 1 Table 7. Three-phase energy measurement I [A] % of INOM [%] % of FS [%] error [%] 22,5 450% 100% 0,097% 16 320% 71% 0,076% 12 240% 53% 0,040% 10 200% 45% 0,035% 8 160% 36% -0,008% 5 100% 22% 0,027% 2 40% 9% 0,035% 1 20% 4% -0,065% 0,5 10% 2% -0,087% 0,25 5% 1% -0,096% 0,1 2% 0,4% -0,087% 0,05 1% 0,2% -0,096% 0,025 0,5% 0,1% -0,096% 0,01 0,2% 0,04% -0,352% 0,005 0,1% 0,02% -0,435% 0,0025 0,05% 0,01% -0,487% |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|