9 / 39 page ![]() DocID025557 Rev 1 9/39 AN4402 Active clamp of the L99MC6 and L9733 38 2.2.2 Case 2: VBAT ≥ VCL_LS - VCL_HS At the turn-off, the evolution of the voltage across the inductor causes an increase of VDS until VDS = VCL_LS. Then, the gate-drain clamp is activated (see Figure 5), like for a low-side switch. VDS is maintained at VCL_LS = VZENER_HS + VF + VGS_TH. Since VS = VBAT - VCL_LS > - VCL_HS, this prevents the activation of the gate-source clamp. Figure 5. L99MC6 high-side during the turn-off, VBAT > VCL_LS - VCL_HS Case 2 corresponds to a demagnetization of the inductive load for VBAT ≥ 16 V for the L99MC6 and for VBAT ≥ 36 V for the L9733. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|