12 / 48 page ![]() 12 Control Characteristics: Transmitter/Receiver The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted. Typical values are for Tc = 40°C, Vcc33 = 3.3 V and Vcc25 = 2.5 V. Parameter Symbol Min Typ Max Units Reference Control* Input Voltage Hysteresis LVTTL Vhys 0.4 V Control* Input Current LVTTL Iin -125 125 µA 0 V < Vin < Vcc33 Control* Output Voltage Low LVTTL Vol 0.4 V Iol = 2mA Control* Output Current High-Z Ioh -10 10 µA 0 V < Vin < Vcc33 Address Assert Time 100 ms 1 Interrupt Assert Time tINTL ON 200 ms 2, Figure 20 Interrupt Pulse Width tINTL PW 5 µs 3, Figure 20 Interrupt De-assert Time tINTL OFF 500 µs 4, Figure 20 Reset Assert Time tRSTL ON 100 µs 5, Figure 19 Reset De-assert Time tRSTL OFF 500 ms 6, Figure 19 Initialization Time TWS Interfaces 500 ms Figure 18 TWS Data In Set Up Time tSU:SDA 0.10 µs 7, Figure 17 TWS Data In Hold Time tHD:SDA 0 µs 8, Figure 17 TWS Clock Low to Data Out Valid tAA 0.10 0.90 µs 9, Figure 17 TWS Data Out Hold Time tDH 50 ns 10, Figure 17 TWS Data Output Rise Time tr SDA 0.30 µs Figure 17, Measured between 0.8V and 2.0V TWS Data Output Fall Time tf SDA 0.30 µs TWS Interface Timing See Atmel Two-Wire Serial EEPROM, e.g. AT24C01A TWS Write Cycle Time twr 40ms Notes: * Control signals include Adr[2:0], IntL, ResetL, SCL and SDA. 1. This is the module response time from a change in module address, Adr[2:0], to response to TWS communication using the new address. 2. This is the module response time from occurrence of interrupt generating event to IntL assertion, Vout:IntL = Vol. 3. Pulse or static level can be selected for IntL. Pulse mode is default. See Memory Map. 4. This is the module response time from clear on read operation, measured from falling SCL edge after stop bit of read transaction, until Vout:IntL = Voh where IntL is in static mode. 5. Assertion of ResetL activates a complete module reset, i.e. module returns to factory default and non-volatile control settings. While ResetL is Low, Tx and Rx outputs are disabled and the module does not respond to the TWS interface. 6. This is the response time from ResetL de-assertion to resumption of operation. 7. Data In Set Up Time is measured from Vil(max)SDA or Vih(min)SDA to Vil(max)SCL. 8. Data In Hold Time is measured from Vil(max)SCL to Vil(max)SDA or Vih(min)SDA. 9. Clock Low to Data Out Time is measured from Vil(max)SCL to Vol(max)SDA or Voh(min)SDA. 10. Data Out Hold Time is measured from Vil(max)SCL to Vol(max)SDA or Voh(min)SDA. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |