39 / 48 page ![]() 39 Address Type Field Name/Description Byte Bit 80-81 all RO Rx Optical Input, Pave, Monitor Channel 3: Optical power in 0.1 µW units coded as 16 bit unsigned integer, Byte 80 is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range. 82-83 all RO Rx Optical Input, Pave, Monitor Channel 2: Optical power in 0.1 µW units coded as 16 bit unsigned integer, Byte 82 is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range. 84-85 all RO Rx Optical Input, Pave, Monitor Channel 1: Optical power in 0.1 µW units coded as 16 bit unsigned integer, Byte 84 is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range. 86-87 all RO Rx Optical Input, Pave, Monitor Channel 0: Optical power in 0.1 µW units coded as 16 bit unsigned integer, Byte 86 is MSB. Tolerance is ± 3dB for -10 dBm to -1.0 dBm range. 88-89 all RO Elapsed (Power-on) Operating Time: Elapsed time in 2 hour units coded as 16 bit unsigned integer, Byte 88 is MSB, Tolerance is ± 10% 90 all RWv Reserved: Coded 00h 91 7-1 RWv Reserved: Coded 0000000b 91 0 RWv Receiver Reset: Writing 1 return all registers except non-volatile RW to factory default values. Reads 0 after operation. 92 7-4 RWv Reserved: Coded 0000b 92 3 RWv Rx Channel 11 Disable: Writing 1 deactivates the electrical output, Default is 0. 92 2 RWv Rx Channel 10 Disable: Writing 1 deactivates the electrical output, Default is 0. 92 1 RWv Rx Channel 9 Disable: Writing 1 deactivates the electrical output, Default is 0. 92 0 RWv Rx Channel 8 Disable: Writing 1 deactivates the electrical output, Default is 0. 93 7 RWv Rx Channel 7 Disable: Writing 1 deactivates the electrical output, Default is 0. 93 6 RWv Rx Channel 6 Disable: Writing 1 deactivates the electrical output, Default is 0. 93 5 RWv Rx Channel 5 Disable: Writing 1 deactivates the electrical output, Default is 0. 93 4 RWv Rx Channel 4 Disable: Writing 1 deactivates the electrical output, Default is 0. 93 3 RWv Rx Channel 3 Disable: Writing 1 deactivates the electrical output, Default is 0. 93 2 RWv Rx Channel 2 Disable: Writing 1 deactivates the electrical output, Default is 0. 93 1 RWv Rx Channel 1 Disable: Writing 1 deactivates the electrical output, Default is 0. 93 0 RWv Rx Channel 0 Disable: Writing 1 deactivates the electrical output, Default is 0. 94 7-4 RWv Reserved: Coded 0000b 94 3 RWv Squelch Disable Channel 11: Writing 1 inhibits squelch for the channel, Default is 0. 94 2 RWv Squelch Disable Channel 10: Writing 1 inhibits squelch for the channel, Default is 0. 94 1 RWv Squelch Disable Channel 9: Writing 1 inhibits squelch for the channel, Default is 0. 94 0 RWv Squelch Disable Channel 8: Writing 1 inhibits squelch for the channel, Default is 0. 95 7 RWv Squelch Disable Channel 7: Writing 1 inhibits squelch for the channel, Default is 0. 95 6 RWv Squelch Disable Channel 6: Writing 1 inhibits squelch for the channel, Default is 0. 95 5 RWv Squelch Disable Channel 5: Writing 1 inhibits squelch for the channel, Default is 0. 95 4 RWv Squelch Disable Channel 4: Writing 1 inhibits squelch for the channel, Default is 0. 95 3 RWv Squelch Disable Channel 3: Writing 1 inhibits squelch for the channel, Default is 0. 95 2 RWv Squelch Disable Channel 2: Writing 1 inhibits squelch for the channel, Default is 0. 95 1 RWv Squelch Disable Channel 1: Writing 1 inhibits squelch for the channel, Default is 0. 95 0 RWv Squelch Disable Channel 0: Writing 1 inhibits squelch for the channel, Default is 0. 96 7-6 RWv Rate Select Channel 11: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00 96 5-4 RWv Rate Select Channel 10: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00 96 3-2 RWv Rate Select Channel 9: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00 96 1-0 RWv Rate Select Channel 8: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00 97 7-6 RWv Rate Select Channel 7: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00 97 5-4 RWv Rate Select Channel 6: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00 97 3-2 RWv Rate Select Channel 5: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00 97 1-0 RWv Rate Select Channel 4: Write 00 for max. BW, 01 for SDR BW, rest reserved. Default is 00 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |