26 / 64 page ![]() E5 @Z 26 Operation Setting Levels Diagram This diagram shows all of the setting levels. To move to the advanced function setting level, you must enter passwords. Some parameters are not displayed depending on the protect level setting and the conditions of use. Control stops when you move from the operation level to the initial setting level. Note: 1. Moves to operation level by software reset. 2. From the manual control level, key operations can be used to move to the operation level only. Error Displays (Troubleshooting) When an error occurs, the No.1 display shows the error code. Take necessary measure according to the error code, referring the table below. Note: 1. If the input value exceeds the display limit ( −1999 to 9999), though it is within the control range, will be displayed under −1999 and above 9999. Under these conditions, control output and alarm output will operate normally. For details on the control range, refer to the E5CZ/E5CZ-U/E5AZ/E5EZ Digital Temperature Controllers User's Manual (Cat. No. H207). 2. These errors are displayed only when the PV/SP is displayed. Errors are not displayed in other display modes. No. 1 display Meaning Action Output status at error Control outputs Alarm outputs s.err (S. Err) Input error (See note 2.) Check the wiring of inputs for miswiring, disconnections, and short-circuits and check the input type. OFF Operates as above the upper limit. A/D converter error (See note 2.) Check for an input error and then cycle the power supply. If the same error is still displayed, repairs will be necessary. If the Temperature Controller is normal after cycling the power supply, the error may have been caused by noise. Check for noise being generated nearby. OFF OFF e111 (E111) Memory error Cycle the power supply. If the same error is still displayed, repairs will be necessary. If the Temperature Controller is normal after cycling the power supply, the error may have been caused by noise. Check for noise being generated nearby. OFF OFF h.err (H. Err) HB error (See note 2.) OFF OFF (See note 2.) (See note 1.) Power ON Started in manual mode. Manual mode Press the O Key for at least 1 s. Press the O Key for at least 1 s; display will flash. Press the Ol Key for at least 3 s while a-m Manual Control Level Operation Level Press the O Key for at least 1 s. Initial Setting Level Press the O Key for at least 1 s. Advanced Function Setting Level Input password. Set value −169 Press the O Key less than 1 s. Communi- cations Setting Press the O Key for at least 1 s; display will flash. Press the O Key for at least 3 s. Control stops. Press the O Key for less than 1 s. Adjustment Level Press the O + M Keys for at least 1 s. Press the O + M keys; display will flash. Press the O + M Keys for at least 3 s. (See note.) Protect level Note: The time taken to move to the protect level can be adjusted by changing the "Move to protect level time" Control in progress Level change Not displayed for some models Control stopped Started in automatic mode. a-m C 25 100 C 25 100 C |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |