50 / 64 page ![]() E5EZ-PRR 50 Parameter Flow • In each level, if you press the mode key on the final parameter, you will return to the parameter at the top of the level. Advanced function setting level init off en-m 1 Parameter initialization none stop Event input assignment 1 Event input assignment 2 ospu off rest a al1n n-o Multi-SP uses on off Alarm 1 open in alarm Alarm 1 hysteresis al2n n-o Alarm 2 open in alarm Alarm 2 hysteresis alh1 02 alh2 02 C C a1lt off Alarm 1 latch a2lt off Alarm 2 latch Alarm 2 OFF delay Additional MV for stop/error a2of 0 Decimal point is Celsius, and is Fahrenheit Temperature unit °C / °F Input type in-t 5 l.ini Scaling upper limit Scaling lower limit in-l 0 in-h 100 Initial setting level dp 0 l. l. l. prlt 3 Move to protect level time Input error output cjc on Cold junction compensation method MB command logic switching Alarm 1 ON delay Alarm 2 ON delay sero off a1on 0 off a2on 0 Alarm 1 OFF delay a1of 0 l. l. l. l. l. l. l. on oanl on p-db 0 l. l. l. alfa 0.65 l. l. l. l. l. l. l. l. l. l. l. l. off Process value dead band Valve opening display Manual MV Limits in effect l.ini l.ini l.ini d-u c sl-h 1300 sl-l -200 SP upper limit SP lower limit Direct / reverse operation Direct operation: on-d Reverse operation: or-r Alarm 1 type alt2 2 Alarm 2 type Closed / floating Floating: flot Closed: clos Motor calibration Motor calibration: on Cancel: off alt1 2 clfl flot calb off Travel time mot 30 l.ini l.ini l.ini l.ini l.ini l.ini l.ini l.ini l.ini 0 Input digital filter Set the time constant, in units of s α 2 PID parameters Additional PV display Displayed first in the operation level off inf 00 l. l. ret off l. ON/OFF setting of alarm output 1 ON/OFF setting of alarm output 2 Activate alarm latch For analog input Limit the set point Select alarm mode C C C Number of multi-SP uses Select 2 or 4. Input setting: Multi-SP/RUN/ STOP Standby sequence reset Reset conditions after standby sequence is canceled. Switch to advanced function setting level To switch to the advanced function setting level, the initial setting/ communications protect parameters must be set to 0. Automatic display return time Automatic return to operation level when the keys on the front panel are operated. Alarm ON/OFF delays |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |