19 / 20 page ![]() 19 EB3L Lamp Barrier Precautions for Operation 1. Installation of EB3L Lamp Barriers (1) The EB3L can be installed in any direction. (2) Install the EB3L lamp barrier in a safe area (non-hazard- ous area) in accordance with intrinsic safety ratings and parameters. To avoid mechanical shocks, install the EB3L in an enclosure which suppresses shocks. (3) When installing or wiring the EB3L, prevent electromag- netic and electrostatic inductions in the intrinsically safe circuit. Also prevent the intrinsically safe circuits from contacting with another intrinsically safe circuit and any other circuits. Maintain at least 50 mm clearance, or provide a metallic separating board between the intrinsically safe circuit and non-intrinsically safety circuit. When providing a metallic separating board, make sure that the board fits closely to the enclosure (top, bottom, and both sides). Allowable clearance between the enclosure and board is 1.5 mm at the maximum. The clearance of 50 mm between the intrinsically safe circuit and non-intrinsically safe circuit may not be suffi- cient when a motor circuit or high-voltage circuit is installed nearby. In this case, provide a wider clearance between the circuits referring to 6 (3) “Minimum Parallel Distance between the Intrinsically Safe Circuit and Other Circuits.” (4) In order to prevent contact between intrinsically safe cir- cuits and non-intrinsically safe circuits, mount EB3L units with terminals arranged in the same direction. (5) Maintain at least 6 mm (or 3 mm according to IEC60079-11: 1999) clearance between the terminal of intrinsically safe circuit and the grounded metal part of a metal enclosure, and between the relay terminal block of an intrinsically safe circuit and the grounded metal part of a metal enclosure. (6) For installing the EB3L, mount on a 35-mm-wide DIN rail or directly on a panel using screws. The EB3L can be installed in any direction. Make sure to install securely to withstand vibration. When mounting on a DIN rail, push in the clamp completely. Use the BNL5 mounting clips on both sides of the EB3L to prevent from moving side- ways. (7) Excessive extraneous noise may cause malfunction and damage to the EB3L. When extraneous noise activates the voltage limiting circuit (thyristor), remove the noise source and restore the power. 2. Terminal Wiring (1) Using a ø5.5 mm or smaller screw driver, tighten the ter- minal screws (including unused terminal screws) to a torque of 0.6 to 1.0 N·m (recommended value). (2) Make sure that IP20 is achieved when wiring. Use insu- lation tubes on bare crimping terminals. (3) To prevent disengaged wires from contacting with other intrinsically safe circuits, bind together the wires of one intrinsically circuit. (4) When the adjacent terminal is connected to another intrinsically safe circuit, provide an insulation distance of at least 6 mm. 3. Signal Input (1) Connect the EB3L to the switches or output equipment which have a low leakage current (0.1 mA maximum). (2) The EB3L is equipped with power supply. Do not apply external power to the EB3L. (3) When connecting the EB3L’s of connector type in paral- lel, make sure that the same power supply is used. When using C1 and C2 terminals to supply power to outside equipment, maintain the current at 50 mA maxi- mum. 4. Power Voltage (1) Do not apply an excessive power voltage, otherwise the EB3L may be damaged. (2) The EB3L of AC power type may operate at a low volt- age (approx. 20V). 5. Pilot Lights and Buzzers in the Hazardous Area (1) EB3P and IPL1 units shown on page 12 can be used with the EB3L. (2) Install the EB3P and IPL1 units on enclosures of IP20 or higher protection. (3) When wiring, make sure of correct polarities of the EB3P and IPL1. (4) Certification mark is supplied with the units. Attach it on the visible area of the EB3P or IPL1 (for Japan applica- tion). (5) Magnesium content of metallic enclosure must be 6% or less (steel and aluminum are acceptable). (6) The maximum exposed area of plastic enclosure is as follows. IIC: 20 cm2 maximum IIB: 100 cm2 maximum When the enclosure has a wider exposed area, attach a caution label as shown below. Intrinsically Safe Circuit Intrinsically Safe Circuit Non-intrinsically Safe Circuit EB3L EB3L EB3L EB3L EB3L Caution To prevent electrostatic charges, do not rub the enclosure sur face during operation. Use a soft cloth dipped with water for cleaning. EB3C-3L catalog Page 19 Monday, February 13, 2006 1:44 PM |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |