| 数据搜索系统,热门电子元器件搜索 |
|
EB3C 数据表(PDF) 5 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
EB3C 数据表(HTML) 5 Page - List of Unclassifed Manufacturers |
|
5 / 20 page ![]() 5 EB3C Relay Barrier Explosion-Protection and Electrical Specifications Note: Values in ( ) are those approved by TIIS (Technology Institution of Industrial Safety, Japan). Certification No. Note: For details about switches, see “Switch Explosion-Protection Specifica- tions” on page 5 and “3. Switches in the Hazardous Area” on page 9. General Specifications Switch Explosion-Protection Specifications (TIIS Japan) Simple apparatuses in accordance with relevant standards of each country can be installed in the hazardous area and connected to the EB3C located in the safe area. In Japan, any switches, though regarded as simple apparatuses, must be cer- tified for explosion-proof devices. EB9Z-A and EB9Z-A1 are IDEC’s generic Type No. of any single apparatuses certified by TIIS Japan for use with the EB3C, there- fore simple apparatuses with specifications shown below can be used as those approved by the Japanese explosion-proof certification. Note: For details, see “3. Switches in the Hazardous Area” on page 9. Explosion Protection Intrinsic safety type (IEC compliant) [Exia] II C Degree of Protection IP20 (IEC60529) Relay Barrier Safe indoor place (non-hazardous area) Switch For zone 0, 1, 2 hazardous areas Non-intrinsically Safe Circuit Maximum Voltage (Um) 250V AC 50/60Hz, 250V DC Wiring Method 1-channel Separate Wiring 16-channel Common Wiring Rated Operating Voltage 12V DC ±10% Rated Operating Current 10 mA DC ±20% Maximum Output Voltage (Uo) 13.2V DC Maximum Output Current (lo) 14.2 mA 227.2 mA Maximum Output Power (Po) 46.9 mW 750 mW Maximum External Inductance (Lo) (Note) 175 (125) mH 0.68 (0.68) mH Maximum External Capacitance (Co) (Note) 900 (740) nF Allowable Wiring Resistance (Rw) 300 Ω 600/(n+1) Ω (n = number of common channels) Maximum Channels per Common Line –16 Contact Configuration 1NO Rated Insulation Voltage (Ui) 250V AC, 125V DC Thermal Current (lth) 3A (common terminal: 8A) Resistive Load AC: 750 VA, DC: 72W Inductive Load AC: 750 VA (cos ø = 0.3 to 0.4) DC: 48W (L/R = 7 ms) Resistive Load 250V AC 3A, 24V DC 3A Inductive Load 250V AC 3A (cos ø = 0.3 to 0.4) 24V DC 2A (L/R = 7 ms) Minimum Applicable Load 0.1V DC, 0.1 mA (reference value) Contact Resistance 50 m Ω maximum (initial value) Turn ON Time 12 ms maximum (rated voltage) Turn OFF Time 10 ms maximum (rated voltage) Mechanical Life 20,000,000 operations minimum (at 18,000 operations/hour, without load) Electrical Life 100,000 operations minimum (at 1,800 operations/hour, rated load) Short-circuit Protection None Rated Voltage 24V DC Maximum Voltage 30V DC Maximum Current 100 mA (connector type: 15 mA) Leakage Current 0.1 mA maximum Voltage Drop 1V maximum Clamping Voltage 33V (1W) Inrush Current 0.5A maximum (1 sec) Turn ON Time 0.1 ms maximum (resistive load) Turn OFF Time 0.4 ms (typical) (resistive load) Short-circuit Protection None Certification Organization Explosion Protection Certification No. FM Class I, II, III Div. 1 Group A, B, C, D, E, F, G 3015417 (terminal type) 3019223 (connector type) Class I, Zone 0 AEx [ia] IIC CSA Class I Div. 1 Group A, B, C, D 166730 NEMKO [EExia] II C Nemko 02ATEX279 TIIS Japan Relay barrier: [Exia] II C C15753 Switch (EB9Z-A): Exia II CT6 C15758 Switch (EB9Z-A1): Exia II BT6 C15961 ClassNK Exia II C 02T606 Power Voltage Type AC Power Type DC Power Type Rated Power Voltage 100 to 240V AC 24V DC Allowable Voltage Range 85 to 264V AC 21.6 to 26.4V DC Rated Frequency 50/60 Hz (allowable range: 47 to 63 Hz) — Inrush Current 10A (100V AC) 20A (200V AC) 10A Dielectric Strength (1 minute, 1 mA) Between intrinsically safe circuit and non-intrinsically safe circuit:1500V AC Between AC power and output terminal: 1500V AC Between DC power and transistor output terminal: 1000V AC Operating Temperature –20 to +60°C (no freezing) Storage Temperature –20 to +60°C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Atmosphere 800 to 1100 hPa Pollution Degree 2 (IEC60664) Insulation Resistance 10 M Ω minimum (500V DC megger, between the same poles as the dielectric strength) Damage Limits Panel mounting: 10 to 55 Hz, amplitude 0.75 mm DIN rail mounting: 10 to 55 Hz, amplitude 0.35 mm Operation Extremes (relay output only) Panel mounting: 10 to 55 Hz, amplitude 0.5 mm DIN rail mounting: 10 to 55 Hz, amplitude 0.35 mm Damage Limits Panel mounting: 500 m/s2 (3 times each on X, Y, Z) DIN rail mounting: 300 m/s2 (3 times each on X, Y, Z) Terminal Style M3 screw terminal Mounting 35-mm-wide DIN rail or panel mounting (M4 screw) Power Consumption (approx.) 9.6 VA (EB3C-R10A at 200V AC) 4.8 W (EB3C-R16CD at 24V DC) Weight (approx.) 0.39 kg (EB3C-R16CD) Switch Type No. EB9Z-A EB9Z-A1 Explosion Proof Exia II CT6 Exia II BT6 Operating Temperature –20 to +60°C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Degree of Protection IP20 Dielectric Strength 500V AC, 1 mA Intrinsic Safety Ratings and Parameters 1-channel Separate Wiring Maximum input voltage (Ui): 13.2V Maximum input current (Ii): 14.2 mA Maximum input power (Pi): 46.9 mW Internal inductance (Li): ≤ 5 µH Internal capacitance (Ci): ≤ 2 nF 16-channel Common Wiring Maximum input voltage (Ui): 13.2V Maximum input current (Ii): 227.2 mA Maximum input power (Pi): 750 mW Internal inductance (Li): ≤ 80 µH Internal capacitance (Ci): ≤ 32 nF Enclosure Material Metallic: Magnesium content must be 6% or less (steel and aluminum are acceptable) Plastic: Switch operator exposed area IIC: 20 cm2 maximum IIB: 100 cm2 maximum When the switch has a wider exposed area, attach a caution label as shown at right. Switch Ratings Contact rating: Ui, Ii minimum Contact resistance: 0.5 Ω maximum Cross sectional area of wire: 0.000962 mm2 maximum Printed circuit board: Thickness 0.5 mm minimum Copper foil width 0.15 mm minimum Thickness 18 µm minimum one/ both side(s) A resistor to prevent contact welding and an LED can be connected to 1-channel separate wiring circuits. Consult IDEC for details. To prevent electrostatic charges, do not rub the switch surface during operation. Use a soft cloth dipped with water for cleaning. Caution Caution Label Example EB3C-3L catalog Page 5 Monday, February 13, 2006 1:44 PM |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |