9 / 20 page ![]() 9 EB3C Relay Barrier Precautions for Operation 1. Installation of EB3C Relay Barriers (1) The EB3C can be installed in any direction. (2) Install the EB3C relay barrier in a safe area (non-hazardous area) in accordance with intrinsic safety ratings and param- eters. To avoid mechanical shocks, install the EB3C in an enclosure which suppresses shocks. (3) When installing or wiring the EB3C, prevent electromag- netic and electrostatic inductions in the intrinsically safe cir- cuit. Also prevent the intrinsically safe circuits from contacting with another intrinsically safe circuit and any other circuits. Maintain at least 50 mm clearance, or provide a metallic separating board between the intrinsically safe circuit and non-intrinsically safety circuit. When providing a metallic separating board, make sure that the board fits closely to the enclosure (top, bottom, and both sides). Allowable clearance between the enclosure and board is 1.5 mm at the maximum. The clearance of 50 mm between the intrinsically safe cir- cuit and non-intrinsically safe circuit may not be sufficient when a motor circuit or high-voltage circuit is installed nearby. In this case, provide a wider clearance between the circuits referring to 5 (3) “Minimum Parallel Distance between the Intrinsically Safe Circuit and Other Circuits.” (4) In order to prevent contact between intrinsically safe circuits and non-intrinsically safe circuits, mount EB3C units with terminals arranged in the same direction. (5) Maintain at least 6 mm (or 3 mm according to IEC60079- 11: 1999) clearance between the terminal of intrinsically safe circuit and the grounded metal part of a metal enclo- sure, and between the relay terminal block of an intrinsically safe circuit and the grounded metal part of a metal enclo- sure. (6) For installing the EB3C, mount on a 35-mm-wide DIN rail or directly on a panel using screws. Make sure to install securely to withstand vibration. When mounting on a DIN rail, push in the clamp completely. Use the BNL5 or BNL6 mounting clips on both sides of the EB3C to prevent from moving sideways. (7) Excessive extraneous noise may cause malfunction and damage to the EB3C. When extraneous noise activates the voltage limiting circuit (thyristor), remove the noise source and restore the power. 2. Terminal Wiring (1) Using a ø5.5 mm or smaller screw driver, tighten the termi- nal screws (including unused terminal screws) to a torque of 0.6 to 1.0 N·m (recommended value). (2) Make sure that IP20 is achieved when wiring. Use insula- tion tubes on bare crimping terminals. (3) To prevent disengaged wires from contacting with other intrinsically safe circuits, bind together the wires of one intrinsically circuit. (4) When the adjacent terminal is connected to another intrinsi- cally safe circuit, provide an insulation distance of at least 6 mm. 3. Switches in the Hazardous Area (For Japan application only) (1) A switch contains the switch contact, enclosure, and inter- nal wiring. A switch contact refers to an ordinary switching device which consists of contacts only, such as a pushbut- ton switch. See below. Applicable Switches Note: For installation in hazardous areas and connection to the EB3C, use switches which are certified, approved, or considered to be simple apparatus in relevant standards in each country. (2) When the switch has internal wiring or lead wire, make sure that the values of internal inductance (Li) and capacitance (Ci) are within the certified values. (3) Enclose the switch contact’s bare live part in an enclosure of IP20 or higher protection. (4) Depending on the explosion-protection specifications according to TIIS Japan, the exposed area of plastic switch operator is limited as follows: • Exia II CT6 (EB9Z-A): 20 cm2 maximum • Exia II BT6 (EB9Z-A1): 100 cm2 maximum (5) Attach the certification mark supplied with the EB3C on the EB9Z-A or EB9Z-A1 switch (for Japan application). (6) Magnesium content of metallic enclosure must be 6% or less (steel and aluminum are acceptable). (7) When the switch operator of plastic enclosure has a wider exposed area than the following limits, attach a caution label as shown below. (8) For the 1-circuit separate wiring, a resistor to prevent reed switch contact welding and an LED miniature pilot lights can be connected in series with the contact. See below. Use the terminal screw of M3 or larger. Applicable Resistor Ratings • Applicable LED Type IDEC’s IPL1 series LED miniature pilot lights. Intrinsically Safe Circuit Intrinsically Safe Circuit Non-intrinsically Safe Circuit EB3C EB3C EB3C EB3C EB3C Control Switches Push-pull Switches Pushbutton, Foot, Trigger, Rocker, Grip Twisting Switches Rotary, Selector, Cam, Drum, Thumb wheel Lever and Slide Switches Toggle, Multidirectional, Wobble stick, Lever, Slide switch Sensing Switches Displacement Switches Microswitch, Limit, Magnetic proximity, Door, Reed, Mercury Level Switches Liquid level Others Pressure, Temperature Resistance 100 Ω maximum Rated Wattage 0.5 to 3W Type Metal (oxide) film resistors To prevent electrostatic charges, do not rub the switch surface during operation. Use a soft cloth dipped with water for cleaning. Caution Caution Label Example IIC: 20 cm2 maximum IIB: 100 cm2 maximum R Reed Switch EB3C EB3C-3L catalog Page 9 Monday, February 13, 2006 1:44 PM |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |