| 数据搜索系统,热门电子元器件搜索 |
|
REF3012 数据表(PDF) 12 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
REF3012 数据表(HTML) 12 Page - Texas Instruments |
|
12 / 26 page ![]() Output Pin Meter V OUT + Sense Line Force Line Load I L Contact and Trace Resistance PRE POST 6 HYST NOM abs V V V = • 10 (ppm) V æ ö - ç ÷ ç ÷ è ø REF3012, REF3020, REF3025, REF3030, REF3033, REF3040 SBVS032G – MARCH 2002 – REVISED NOVEMBER 2015 www.ti.com Feature Description (continued) 8.3.2 Thermal Hysteresis Thermal hysteresis for the REF30xx is defined as the change in output voltage after operating the device at 25°C, cycling the device through the specified temperature range, and returning to 25°C, and can be expressed as shown in Equation 1: where • VHYST = Calculated hysteresis • VPRE = Output voltage measured at 25°C pretemperature cycling • VPOST = Output voltage measured when device has been operated at 25°C, cycled through specified range of –40°C to +125°C, and returned to operation at 25°C. (1) 8.3.3 Temperature Drift The REF30xx exhibits minimal drift error, defined as the change in output voltage over varying temperature. Using the box method of drift measurement, the REF30xx features a typical drift coefficient of 20 ppm from 0°C to 70°C, the primary temperature range of use for many applications. For industrial temperature ranges of –40°C to +125°C, the REF30xx family drift increases to a typical value of 50 ppm. 8.3.4 Noise Performance The REF30xx generates noise less than 50 μVPP between frequencies of 0.1 Hz to 10 Hz, and can be seen in Figure 20 The noise voltage of the REF30xx increases with output voltage and operating temperature. Additional filtering may be used to improve output noise levels; however, ensure the output impedance does not degrade ac performance. 8.3.5 Long-Term Stability Long-term stability refers to the change of the output voltage of a reference over a period of months or years. This effect lessens as time progresses as is apparent by the long term stability curves. The typical drift value for the REF30xx is 24 ppm from 0 hours to 1000 hours, and 15 ppm from 1000 hours to 2000 hours. This parameter is characterized by measuring 30 units at regular intervals for a period of 2000 hours. 8.3.6 Load Regulation Load regulation is defined as the change in output voltage as a result of changes in load current. Load regulation for the REF30xx is measured using force and sense contacts as shown in Figure 25. The force and sense lines tied to the contact area of the output pin reduce the impact of contact and trace resistance, resulting in accurate measurement of the load regulation contributed solely by the REF30xx. For applications requiring improved load regulation, use force and sense lines. Figure 25. Accurate Load Regulation of REF30xx 12 Submit Documentation Feedback Copyright © 2002–2015, Texas Instruments Incorporated Product Folder Links: REF3012 REF3020 REF3025 REF3030 REF3033 REF3040 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |