| 数据搜索系统,热门电子元器件搜索 |
|
LM63 数据表(PDF) 7 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM63 数据表(HTML) 7 Page - National Semiconductor (TI) |
|
7 / 28 page ![]() Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. Note 2: All voltages are measured with respect to GND, unless otherwise noted. Note 3: When the input voltage (VIN) at any pin exceeds the power supplies (VIN < GND or VIN > V+), the current at that pin should be limited to 5 mA. Parasitic components and/or ESD protection circuitry are shown below for the LM63’s pins. The nominal breakdown voltage of D3 is 6.5 V. Care should be taken not to forward bias the parasitic diode, D1, present on pins D+ and D−. Doing so by more than 50 mV may corrupt temperature measurements. An "X" means it exists in the circuit. Pin Name PIN # D1 D2 D3 D4 D5 D6 R1 SNP ESD CLAMP V DD 1X X D+ 2 X X XXX X D− 3 X X XXX X PWM 4 X X X X ALERT/Tach 6X X X X SMBDAT 7 X X X X SMBCLK 8 X X Note 4: Human body model, 100 pF discharged through a 1.5 k Ω resistor. Machine model, 200 pF discharged directly into each pin. See Figure 1 above for the ESD Protection Input Structure. Note 5: Thermal resistance junction-to-ambient when attached to a printed circuit board with 2 oz. foil is 168˚C/W. Note 6: See the URL “http://www.national.com/packaging/” for other recommendations and methods of soldering surface mount devices. Note 7: “Typicals” are at TA = 25˚C and represent most likely parametric norm. They are to be used as general reference values not for critical design calculations. Note 8: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level). Note 9: The supply current will not increase substantially with an SMBus transaction. Note 10: Local temperature accuracy does not include the effects of self-heating. The rise in temperature due to self-heating is the product of the internal power dissipation of the LM63 and the thermal resistance. See (Note 5) for the thermal resistance to be used in the self-heating calculation. Note 11: The output rise time is measured from (VIL max - 0.15 V) to (VIH min + 0.15 V). Note 12: The output fall time is measured from (VIH min + 0.15 V) to (VIL min - 0.15 V). Note 13: Holding the SMBData and/or SMBCLK lines Low for a time interval greater than tTIMEOUT will reset the LM63’s SMBus state machine, therefore setting SMBDAT and SMBCLK pins to a high impedance state. 1.0 Functional Description The LM63 Remote Diode Temperature Sensor with Inte- grated Fan Control incorporates a ∆V BE-based temperature sensor using a Local or Remote diode and a 10-bit plus sign ∆Σ ADC (Delta-Sigma Analog-to-Digital Converter). The pulse-width modulated (PWM) open-drain output, with a pull-up resistor, can drive a switching transistor to modulate the fan. When the ALERT/Tach is programmed to the Tach mode the LM63 can measure the fan speed on the pulses from the fan’s tachometer output. When the ALERT/Tach pin is programmed to the ALERT mode the ALERT open-drain output will be pulled low when the measured temperature exceeds certain programmed limits when enabled. Details are contained in the sections below. The LM63’s two-wire interface is compatible with the SMBus Specification 2.0 . For more information the reader is di- rected to www.smbus.org. In the LM63 digital comparators are used to compare the measured Local Temperature (LT) to the Local High Setpoint user-programmable temperature limit register. The mea- sured Remote Temperature (RT) is digitally compared to the Remote High Setpoint (RHS), the Remote Low Setpoint (RLS), and the Remote T_CRIT Setpoint (RCS) user- programmable temperature limits. An ALERT output will oc- cur when the measured temperature is: (1) higher than either the High Setpoint or the T_CRIT Setpoint, or (2) lower than the Low Setpoint. The ALERT Mask register allows the user to prevent the generation of these ALERT outputs. The temperature hysteresis is set by the value placed in the Hysteresis Register (TH). The LM63 may be placed in a low power Standby mode by setting the Standby bit found in the Configuration Register. In the Standby mode continuous conversions are stopped. In 20057005 FIGURE 1. ESD Protection Input Structure www.national.com 7 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |