10 / 28 page ![]() 1.0 Functional Description (Continued) 1.3 SMBus INTERFACE Since the LM63 operates as a slave on the SMBus the SMBCLK line is an input and the SMBDAT line is bi- directional. The LM63 never drives the SMBCLK line and it does not support clock stretching. According to SMBus specifications, the LM63 has a 7-bit slave address. All bits, A6 through A0, are internally programmed and cannot be changed by software or hardware. The complete slave address is: A6 A5 A4 A3 A2 A1 A0 1 00110 0 1.4 POWER-ON RESET (POR) DEFAULT STATES For information on the POR default states see Section 2.2 LM63 Register Map in Functional Order. 1.5 TEMPERATURE DATA FORMAT Temperature data can only be read from the Local and Remote Temperature registers. The High, Low and T_CRIT setpoint registers are Read/Write. Remote temperature data is represented by an 11-bit, two’s complement word with a Least Significant Bit (LSB) equal to 0.125˚C. The data format is a left justified 16-bit word avail- able in two 8-bit registers: Temperature Digital Output Binary Hex +125˚C 0111 1101 0000 0000 7D00 +25˚C 0001 1001 0000 0000 1900 +1˚C 0000 0001 0000 0000 0100 +0.125˚C 0000 0000 0010 0000 0020 0˚C 0000 0000 0000 0000 0000 −0.125˚C 1111 1111 1110 0000 FFE0 −1˚C 1111 1111 0000 0000 FF00 −25˚C 1110 0111 0000 0000 E700 −55˚C 1100 1001 0000 0000 C900 Local Temperature data is represented by an 8-bit, two’s complement byte with an LSB equal to 1˚C: Temperature Digital Output Binary Hex +125˚C 0111 1101 7D +25˚C 0001 1001 19 +1˚C 0000 0001 01 0˚C 0000 0000 00 −1˚C 1111 1111 FF −25˚C 1110 0111 E7 −55˚C 1100 1001 C9 1.6 OPEN-DRAIN OUTPUTS The SMBDAT, ALERT, and PWM outputs are open-drain outputs and do not have internal pull-ups. A “High” level will not be observed on these pins until pull-up current is pro- vided by an internal source, typically through a pull-up resis- tor. Choice of resistor value depends on several factors but, in general, the value should be as high as possible consis- tent with reliable operation. This will lower the power dissi- pation of the LM63 and avoid temperature errors caused by self-heating of the device. The maximum value of the pull-up resistor to provide the 2.1 V high level is 88.7 k Ω. 1.7 DIODE FAULT DETECTION The LM63 can detect fault conditions caused by the remote diode. If the D+ pin is detected to be shorted to V DD, or open: (1) the Remote Temperature High Byte (RTHB) register is loaded with 127˚C, (2) the Remote Temperature Low Byte (RTLB) register is loaded with 0, and (3) the OPEN bit (D2) in the status register is set. Therefore, if the Remote T_CRIT setpoint register (RCS): (1) is set to a value less than +127˚C and (2) the ALERT Mask is disabled, then the ALERT output pin will be pulled low. If the Remote High Setpoint High Byte (RHSHB) is set to a value less than +127˚C and (2) the ALERT Mask is disabled, then the ALERT will be pulled low. The OPEN bit by itself will not trigger an ALERT. If the D+ pin is shorted to either ground or D−, then the Remote Temperature High Byte (RTHB) register is loaded with −128˚C (1000 0000) and the OPEN bit in the ALERT Status Register will not be set. A temperature reading of −128˚C indicates that D+ is shorted to either ground or D-. If the value in the Remote Low Setpoint High Byte (RLSHB) Register is more than −128˚C and the ALERT Mask is Dis- abled, ALERT will be pulled low. 1.8 COMMUNICATING WITH THE LM63 Each data register in the LM63 falls into one of four types of user accessibility: 1. Read Only 2. Write Only 3. Read/Write same address 4. Read/Write different address A Write to the LM63 is comprised of an address byte and a command byte. A write to any register requires one data byte. Reading the LM63 Registers can take place after the requi- site register setup sequence takes place. See Section 2.1.1 LM63 Required Initial Fan Control Register Sequence. The data byte has the Most Significant Bit (MSB) first. At the end of a read, the LM63 can accept either Acknowledge or 20057009 FIGURE 5. ALERT Output as an SMBus ALERT Temperature Response Diagram www.national.com 10 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |