| 数据搜索系统,热门电子元器件搜索 |
|
AS29F010 数据表(PDF) 9 Page - Micross Components |
|
|
|||||||||||||||||||||||||||||
AS29F010 数据表(HTML) 9 Page - Micross Components |
|
9 / 26 page ![]() FLASH AS29F010 Micross Components reserves the right to change products or specifications without notice. 9 AS29F010 Rev. 2.6 11/10 non-suspended sectors. The system can determine the status of the program operation using the DQ7 or DQ6 status bits, just as in the standard program operation. See “Write Operation Status” for more information. The system may also write the autoselect command se- quence when the device is in the Erase Suspend mode. The device allows reading autoselect codes even at addresses within erasing sectors, since the codes are not stored in the memory array. When the device exits the autoselect mode, the device reverts to the Erase Suspend mode, and is ready for another valid operation. See “Autoselect Command Sequence” for more information. The system must write the Erase Resume command (address bits are “don’t care”) to exit the erase suspend mode and continue the sector erase operation. Further writes of the Resume command are ignored. Another Erase Suspend com- mand can be written after the device has resumed erasing. TABLE 4: Command Definitions Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data 1RA RD 1 XXXX F0 3 555 AA 2AA 55 555 F0 Manufacturer ID 4 555 AA 2AA 55 555 90 X00 1 Device ID 4 555 AA 2AA 55 555 90 X01 20 0 1 4 555 AA 2AA 55 555 A0 PA PD 6 555 AA 2AA 55 555 80 555 AA 2AA 55 555 10 6 555 AA 2AA 55 555 80 555 AA 2AA 55 SA 30 1 XXX B0 1 XXX 30 55 555 90 (SA) X02 4 555 AA 2AA Erase Resume 10 Read 4 Reset 6 Sector Protect Verify 8 Program Chip Erase Sector Erase Erase Suspend 9 Reset 5 Autoselect 7 Bus Cycles 2,3 First Second Third Fourth Fifth Sixth Command Sequence 1 LEGEND: X = Don’t Care RA = Address of the memory location to be read RD = Data read from location RA during read operation PA = Address of the memory location to be programmed. Addresses latch on the falling edge of the WE\ or CE\ pulse, whichever happens later PD = Data to be programmed at location PA. Data latches on the rising edge of WE\ or CE\ pulse, whichever happens first SA = Address of the sector to be verified (in autoselect mode) or erased. Address bits A16-A14 uniquely select any sector. NOTES: 1. See Table 1 for description of bus operations. 2. All values are in hexadecimal. 3. Except when reading array or autoselect data, all command bus cycles are write operations. 4. No unlock or command cycles required when reading array data. 5. The Reset command is required to return to reading array data when device is in the autoselect mode, or if DQ5 goes high (while the device is providing status data). 6. The device accepts the three-cycle reset command sequence for backward compatibility. 7. The fourth cycle of the autoselect command sequence is a read operation. 8. The data is 00h for an unprotected sector and 01h for a protected sector. See “Autoselect Command Sequence” for more information. 9. The system may read in non-erasing sectors, or enter the autoselect mode, when in the Erase Suspend mode. The Erase Suspend command is valid only during a sector erase operation. 10. The Erase Resume command is valid only during the Erase Suspend mode. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |