29 / 44 page ![]() REV. PrG 01/03 PRELIMINARY TECHNICAL DATA ADE7754 – 29 – Figure 36 shows this Apparent Energy accumulation for full scale signals (sinusoidal) on the analog inputs. The three curves displayed, illustrate the minimum time it takes the energy register to roll-over when the individual VA Gain registers contents are all equal to 3FFh, 000h and 800h. The VA Gain registers are used to carry out an apparent power calibration in the ADE7754. As shown, the fastest integration time will occur when the VA Gain registers are set to maximum full scale, i.e., 3FFh. 00,0000h 7F,FFFFh 80,0000h 3F,FFFFh 40,0000h VAENERGY[23:0] Time (seconds) AVAG = BVAG = CVAG = 3FFh 131 262 393 65.5 196.5 327.5 AVAG = BVAG = CVAG = 000h AVAG = BVAG = CVAG = 800h Figure 36 - Energy register roll-over time for full-scale power (Minimum & Maximum Power Gain) Note that the Apparent Energy register contents roll-over to full-scale negative (80,0000h) and continue increasing in value when the power or energy flow is positive - see Figure 36. By using the Interrupt Enable register, the ADE7754 can be configured to issue an interrupt (IRQ) when the Apparent Energy register is half full (positive or negative). Integration times under steady load As mentioned in the last section, the discrete time sample period (T) for the accumulation register is 1.2µs (12/ CLKIN). With full-scale sinusoidal signals on the analog inputs and the VA Gain registers set to 000h, the average word value from each Apparent Power stage is D1B71h - see Apparent Power output range. The maximum value which can be stored in the Apparent Energy register before it over-flows is 2 23 -1or FF,FFFFh. As the average word value is added to the internal register which can store 2 48 - 1 or FFFF,FFFF,FFFFh before it overflows, the integration time under these conditions with VADIV=0 is calculated as follows: Time FFFF FFFF FFFFh DB h ss s = × ×= = ,, .min 31 71 1 2 131 2 11 µ When VADIV is set to a value different from 0, the integra- tion time varies as shown on Equation 23. Time = TimeWDIV=0 x VADIV (23) LINE APPARENT ENERGY ACCUMULATION The ADE7754 is designed with a special Apparent Energy accumulation mode which simplifies the calibration process. By using the on-chip zero-crossing detection, the ADE7754 accumulates the Apparent Power signal in the LVAENERGY register for an integral number of half cycles, as shown in Figure 37. The line Apparent energy accumulation mode is always active. Each one of three phases zero-crossing detection can contrib- ute to the accumulation of the half line cycles. Phase A, B and C zero crossings are taken into account when counting the number of half line cycle by setting to logic one bits 4-6 of the MMODE register. Selecting phases for the Zero crossing counting has also the effect of enabling the Zero-crossing detection, Zero-crossing Time-Out and Period Measure- ment for the corresponding phase as described in the Zero-crossing Detection paragraph. The number of half line cycles is specified in the LINCYC register. LINCYC is an unsigned 16-bit register. The ADE7754 can accumulate Apparent Power for up to 65535 combined half cycles. Because the Apparent Power is inte- grated on the same integral number of line cycles as the Line Active Energy register, these two values can be compared easily - see Energy Scaling. The active and apparent Energy are calculated more accurately because of this precise timing control and provide all the information needed for Reactive Power and Power Factor calculation. At the end of an energy calibration cycle the LINCYC flag in the Interrupt Status register is set. If the LINCYC mask bit in the Interrupt Mask register is enabled, the IRQ output will also go active low. Thus the IRQ line can also be used to signal the end of a calibration. + + Σ CALIBRATION CONTROL LINCYC[15:0] Σ + + Apparent Power Phase A Apparent Power Phase B Apparent Power Phase C ACCUMULATE APPARENT POWER DURING LINCYC ZERO-CROSSINGS 48 0 48 0 LVAENERGY[23:0] VADIV 23 0 LPF1 FROM VA ADC ZEROCROSS DETECT LPF1 FROM VB ADC ZEROCROSS DETECT LPF1 FROM VC ADC ZEROCROSS DETECT MMODE register bit 6 MMODE register bit 4 MMODE register bit 5 Figure 37 - ADE7754 Apparent Energy Calibration |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |