13 / 20 page ![]() Datasheet SHT3x-DIS www.sensirion.com August 2016 - Version 3 13/20 Command Hex code Read Out of status register 0xF32D Table 16 Command to read out the status register (Clear blocks are controlled by the microcontroller, grey blocks by the sensor). Bit Field description Default value 15 Alert pending status '0': no pending alerts '1': at least one pending alert ‘1’ 14 Reserved ‘0’ 13 Heater status ‘0’ : Heater OFF ‘1’ : Heater ON ‘0’ 12 Reserved ‘0’ 11 RH tracking alert ‘0’ : no alert ‘1’ . alert ‘0 10 T tracking alert ‘0’ : no alert ‘1’ . alert ‘0’ 9:5 Reserved ‘xxxxx’ 4 System reset detected '0': no reset detected since last ‘clear status register’ command '1': reset detected (hard reset, soft reset command or supply fail) ‘1’ 3:2 Reserved ‘00’ 1 Command status '0': last command executed successfully '1': last command not processed. It was either invalid, failed the integrated command checksum ‘0’ 0 Write data checksum status '0': checksum of last write transfer was correct '1': checksum of last write transfer failed ‘0’ Table 17 Description of the status register. Clear Status Register All flags (Bit 15, 11, 10, 4) in the status register can be cleared (set to zero) by sending the command shown in Table 18. Command Hex Code Clear status register 0x 30 41 Table 18 Command to clear the status register (Clear blocks are controlled by the microcontroller, grey blocks by the sensor). 4.12 Checksum Calculation The 8-bit CRC checksum transmitted after each data word is generated by a CRC algorithm.Its properties are displayed in Table 19. The CRC covers the contents of the two previously transmitted data bytes. To calculate the checksum onlythese two previouslytransmitted data bytes are used. Property Value Name CRC-8 Width 8 bit Protected data read and/or write data Polynomial 0x31 (x8 + x5 + x4 + 1) Initialization 0xFF Reflect input False Reflect output False Final XOR 0x00 Examples CRC (0xBEEF) = 0x92 Table 19 I2C CRC properties. 4.13 Conversion of Signal Output Measurementdata is always transferred as 16-bitvalues (unsigned integer). These values are already linearized and compensated for temperature and supply voltage effects. Converting those raw values into a physical scale can be achieved using the following formulas. Relative humidityconversion formula (resultin %RH): 1 16 RH 2 S 100 RH Temperature conversion formula (resultin °C & °F): 1 1 16 T 16 T 2 S 315 49 F T 2 S 175 45 C T SRH and ST denote the raw sensor output for humidity and temperature, respectively. The formulas work only correctly when SRH and ST are used in decimal representation. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |