| 数据搜索系统,热门电子元器件搜索 |
|
SHT35 数据表(PDF) 2 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
SHT35 数据表(HTML) 2 Page - List of Unclassifed Manufacturers |
|
2 / 20 page ![]() Datasheet SHT3x-DIS www.sensirion.com August 2016 - Version 3 2/20 1 Sensor Performance Humidity Sensor Specification Parameter Condition Value Units SHT30 Accuracy tolerance1 Typ. 3 % RH Max. Figure 2 - SHT31 Accuracy tolerance1 Typ. 2 % RH Max. Figure 3 - SHT35 Accuracy tolerance1 Typ. ±1.5 % RH Max. Figure 4 - Repeatability2 Low 0.25 % RH Medium 0.15 % RH High 0.10 % RH Resolution Typ. 0.01 % RH Hysteresis at 25°C 0.8 % RH Specified range3 extended4 0 to 100 % RH Response time5 63% 86 s Long-term drift Typ.7 <0.25 % RH/yr Table 1 Humidity sensor specification. Temperature Sensor Specification Parameter Condition Value Units SHT30 Accuracy tolerance1 typ., 0°C to 65°C 0.3 °C SHT31 Accuracy tolerance1 typ., -40°C to 90°C 0.3 °C SHT35 Accuracy tolerance1 typ., -40°C to 90°C ±0.2 °C Repeatability2 Low 0.24 °C Medium 0.12 °C High 0.06 °C Resolution Typ. 0.015 °C Specified Range - -40 to 125 °C Response time 8 63% >2 s Long Term Drift max <0.03 °C/yr Table 2 Temperature sensor specification. 1 For definition of ty pical and maximum accuracy tolerance, pleaserefer to the document “Sensirion Humidity Sensor Specification Statement”. 2 The stated repeatability is 3 times the standard deviation (3σ) of multiple consecutive measurements at the stated repeatability and at constant ambient conditions. It is a measure for the noise on the phy sical sensor output. Different measurement modes allow for high/medium/low repeatability. 3 Specified range refers to the range for w hich the humidity or temperature sensor specification is guaranteed. 4 For details about recommended humidity and temperature operating range, please refer to section 1.1. 5 Time for achiev ing63% of a humidity step function, valid at 25°C and 1m/s airflow. Humidity response time in the application depends on the design-in of the sensor. 6 With activ ated ART function (seesection 4.7) the response time can be improved by a factor of 2. 7 Ty pical value for operation in normal RH/T operating range, see section 1.1. Maximum value is < 0.5 %RH/yr. Higher drift values might occur due to contaminant env ironments with vaporized solvents, out-gassing tapes, adhesives, packagingmaterials, etc. For more details please refer to Handling Instructions. 8 Temperature response times strongly depend on the ty pe of heat ex change, the av ailable sensor surface and the design environment of the sensor in the final application. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |