| 数据搜索系统,热门电子元器件搜索 |
|
AD8556ACPZ-R2 数据表(PDF) 23 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD8556ACPZ-R2 数据表(HTML) 23 Page - Analog Devices |
|
23 / 28 page ![]() AD8556 Data Sheet Parity Error Detection A parity check is used to determine whether the programmed data of an AD8556 is valid, or whether data corruption has occurred in the nonvolatile memory. Figure 50 shows the schematic implemented in the AD8556. VA0 to VA2 is the 3-bit control signal for the second stage gain, VB0 to VB6 is the 7-bit control signal for the first stage gain, and VC0 to VC7 is the 8-bit control signal for the output offset. PFUSE is the signal from the parity fuse, and MFUSE is the signal from the master fuse. The function of the 2-input AND gate (Cell AND2) is to ignore the output of the parity circuit (PAR_SUM signal) when the master fuse is not blown. PARITY_ERROR is set to 0 when MFUSE = 0. In the simulation mode, for example, parity check is disabled. After the master fuse is blown, that is, after the AD8556 is programmed, the output from the parity circuit (PAR_SUM signal) is fed to PARITY_ERROR. When PARITY_ERROR is 0, the AD8556 behaves as a programmed amplifier. When PARITY_ERROR is 1, a parity error is detected, and VOUT is connected to VSS. The 18-bit data signal (VA0 to VA2, VB0 to VB6, and VC0 to VC7) is fed to an 18-input exclusive-OR gate (Cell EOR18). The output of Cell EOR18 is the DAT_SUM signal. If there is an even number of 1s in the 18-bit word, DAT_SUM = 0; and if there is an odd number of 1s in the 18-bit word, DAT_SUM = 1. See Table 13 for examples. After the second stage gain, first stage gain, and output offset are programmed, compute DAT_SUM and set the parity bit equal to DAT_SUM. If DAT_SUM is 0, the parity fuse should not be blown in order for the PFUSE signal to be 0. If DAT_SUM is 1, the parity fuse should be blown to set the PFUSE signal to 1. The code to blow the parity fuse is: 1000 0000 0001 10 11 10 0000 0100 01111111 1110. After setting the parity bit, the master fuse can be blown to prevent further programming, using the code: 1000 0000 0001 10 11 10 0000 0001 0111 1111 1110. Signal PAR_SUM is the output of the 2-input exclusive-OR gate (Cell EOR2). After the master fuse is blown, set PARITY_ERROR to PAR_SUM. As previously mentioned, the AD8556 behaves as a programmed amplifier when PARITY_ERROR = 0 (no parity error). On the other hand, VOUT is connected to VSS when a parity error is detected, that is, when PARITY_ERROR = 1. IN01 IN02 IN03 IN04 IN05 IN06 IN07 IN08 IN09 IN10 IN11 IN12 IN13 IN14 IN15 IN16 IN17 IN18 VA0 VA1 VA2 VB0 VB1 VB2 VB3 VB4 VB5 VB6 VC0 VC1 VC2 VC3 VC4 VC5 VC6 VC7 EOR18 OUT I0 DAT_SUM PAR_SUM PFUSE MFUSE IN1 IN2 EOR2 AND2 IN1 IN2 PARITY_ERROR I1 OUT I2 OUT Figure 50. Functional Circuit of AD8556 Parity Check Table 13. Examples of DAT_SUM Second Stage Gain Code First Stage Gain Code Output Offset Code Number of Bits with 1 DAT_SUM 000 000 0000 0000 0000 0 0 000 000 0000 1000 0000 1 1 000 000 0000 1000 0001 2 0 000 000 0001 0000 0000 1 1 000 100 0001 0000 0000 2 0 001 000 0000 0000 0000 1 1 001 000 0001 1000 0000 3 1 111 111 1111 1111 1111 18 0 Rev. B | Page 22 of 27 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |