9 / 19 page ![]() PISA11.CLASS2 PISA11-Series PROTECTION MODULE 24V, 4 OUTPUTS 8. OUTPUT-OK RELAY CONTACT This relay contact is closed when the input voltage is sufficient and the outputs are not shutdown. Threshold voltage typ. 21.4Vdc Required voltage to power the relay and to close the relay contact. The outputs must also not be shutdown. Contact ratings max. 30Vdc, 1.0A Resistive load max. 30Vac, 0.5A Resistive load min. 1mA at 5Vdc Galvanic isolation nom. 500Vac Test voltage: Signal path to power path 9. ON/OFF AND RESET SIGNAL INPUT This signal input is galvanically isolated with an integrated optocoupler and works in the same manner as the reset and ON/OFF button. The ON/OFF function has no safety feature included. In a failure mode (outputs have shutdown), the outputs can be turned on again by applying a voltage for more than 1 second. 12 (+) 5.1V 3mA Inhibit 11 (-) In normal mode (outputs have not shutdown), a short (> 50ms) voltage pulse will turn all outputs ON or OFF. The unit will be shipped (factory setting) with the outputs turned-on. Signal voltage max. 30Vdc Signal current typ. 3mA Active current limited max. 6mA active current limited Threshold voltage levels min 6Vdc Voltages above this level will trigger the inhibit or max. 10Vdc reset. Galvanic isolation nom. 500Vac Test voltage: signal path to power path 10. SYNCHRONIZATION OF MULTIPLE PISA MODULES If multiple PISA modules are used on the same power supply, it is recommended to connect the sync. bus of all modules together. If one unit shuts down due to the protection function of the input voltage protection circuit (safeguard), all other modules will shutdown too. This avoids a false interpretation of which output channel caused the problem. If the sync. terminals are not linked, the module with the highest safeguard protection voltage level (caused by tolerances) would shutdown first regardless whether the failure was caused by this module or not. 1 2 3 4 Outputs Input + - - sync. 16 15 14 13 12 11 Reset + - OK PISA11 Input L1 L2 L3 PE QT40.241 Power Supply Output + - 1 2 3 4 Outputs Input + - - sync. 16 15 14 13 12 11 Reset + - OK PISA11 1 2 3 4 Outputs Input + - - sync. 16 15 14 13 12 11 Reset + - OK PISA11 1 2 3 4 Outputs Input + - - sync. 16 15 14 13 12 11 Reset + - OK PISA11 Please note: If the cause for the shutdown was an over- current of one individual channel only this module will shutdown and the other modules will stay on. In this case the sync. line has no impact on the other modules. May 2014 / Rev. 1.7 DS-PISA11.CLASS2 - data sheet - All parameters are specified at 24Vdc input, 25°C ambient temperature and a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278-0 Germany 9/19 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |