8 / 18 page ![]() 1.0 Functional Description The LM92 temperature sensor incorporates a band-gap type temperature sensor, 13-bit ADC, and a digital comparator with user-programmable upper and lower limit values. The comparator activates either the INT line for temperatures outside the T LOW and THIGH window, or the T_CRIT_A line for temperatures which exceed T_CRIT. The lines are pro- grammable for mode and polarity. 1.1 TEMPERATURE COMPARISON LM92 provides a window comparison against a lower (T LOW) and upper (T HIGH) trip point. A second upper trip point (T_CRIT) functions as a critical alarm shutdown. Figure 3 depicts the comparison function as well as the modes of op- eration. 1.1.1 STATUS BITS The internal Status bits operate as follows: “True”: Temperature above a T HIGH or T_CRIT is “true” for those respective bits. A “true” for T LOW is temperature below T LOW. “False”: Assuming temperature has previously crossed above T HIGH or T_CRIT, then the temperature must drop be- low the points corresponding T HYST (T HIGH −T HYST or T_CRIT − T HYST) in order for the condition to be false. For T LOW, assuming temperature has previously crossed below T LOW, a “false” occurs when temperature goes above TLOW +T HYST. The Status bits are not affected by reads or any other ac- tions, and always represent the state of temperature vs. set- points. 1.1.2 HARDWIRE OUTPUTS The T_CRIT_A hardwire output mirrors the T_CRIT_A flag, when the flag is true, the T_CRIT_A output is asserted at all times regardless of mode. Reading the LM92 has no effect on the T_CRIT_A output, although the internal conversion is restarted. The behavior of the INT hardwire output is as follows: Comparator Interrupt Mode (Default): User reading part resets output until next measurement completes. If condition is still true, output is set again at end of next conversion cycle. For example, if a user never reads the part, and tem- perature goes below T LOW then INT becomes active. It would stay that way until temperature goes above T LOW + T HYST. However if the user reads the part, the output would be reset. At the end of the next conversion cycle, if the con- dition is true, it is set again. If not, it remains reset. Event Interrupt Mode: User reading part resets output un- til next condition ″event″ occurs (in other words, output is only set once for a true condition, if reset by a read, it re- mains reset until the next triggering threshold has been crossed). Conversely, if a user never read the part, the out- put would stay set indefinitely after the first event that set the output. An “event” for Event Interrupt Mode is defined as: 1. Transitioning upward across a setpoint, or 2. Transitioning downward across a setpoint’s correspond- ing hysteresis (after having exceeded that setpoint). For example, if a user never read the part, and temperature went below T LOW then INT would become active. It would stay that way forever if a user never read the part. However if the user read the part, the output would be reset. Even if the condition is true, it will remain reset. The tem- perature must cross above T LOW +THYST to set the output again. In either mode, reading any register in the LM92 restarts the conversion. This allows a designer to know exactly when the LM92 begins a comparison. This prevents unnecessary In- terrupts just after reprogramming setpoints. Typically, sys- tem Interrupt inputs are masked prior to reprogramming trip points. By doing a read just after resetting trip points, but prior to unmasking, unexpected Interrupts are prevented. Avoid programming setpoints so close that their hysteresis values overlap. An example would be that with a T HYST value of 2 ˚C then setting T HIGH and TLOW to within 4 ˚C of each other will violate this restriction. To be more specific, with T HYST set to 2 ˚C assume T HIGH set to 64 ˚C. If TLOW is set equal to, or higher than 60 ˚C this restriction is violated. 1.2 DEFAULT SETTINGS The LM92 always powers up in a known state. LM92 power up default conditions are: 1. Comparator Interrupt Mode 2. T LOW set to 10 ˚C 3. T HIGH set to 64 ˚C 4. T_CRIT set to 80 ˚C 5. T HYST set to 2 ˚C 6. INT and T_CRIT_A active low 7. Pointer set to “00”; Temperature Register The LM92 registers will always reset to these default values when the power supply voltage is brought up from zero volts as the supply crosses the voltage level plotted in the follow- ing curve. The LM92 registers will reset again when the power supply drops below the voltage plotted in this curve. 1.3 SERIAL BUS INTERFACE The LM92 operates as a slave on the Serial Bus, so the SCL line is an input (no clock is generated by the LM92) and the SDA line is a bi-directional serial data line. According to Se- rial Bus specifications, the LM92 has a 7-bit slave address. The five most significant bits of the slave address are hard wired inside the LM92 and are “10010”. The two least signifi- cant bits of the address are assigned to pins A1–A0, and are set by connecting these pins to ground for a low, (0); or to +V S for a high, (1). Average Power on Reset Voltage vs Temperature DS101051-18 www.national.com 8 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |