| 数据搜索系统,热门电子元器件搜索 |
|
MAX1739EEP 数据表(PDF) 24 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1739EEP 数据表(HTML) 24 Page - Maxim Integrated Products |
|
24 / 26 page ![]() Wide Brightness Range CCFL Backlight Controllers 24 ______________________________________________________________________________________ Status Register [STATUS1–STATUS0] (POR = 0b11) The status register returns information on fault condi- tions. If a lamp is not connected to the secondary of the transformer, the MAX1739 will detect that the lamp cur- rent has not exceeded the CSAV detection threshold and after 2 seconds will clear the STATUS1 bit (see Lamp-Out Detection). The STATUS1 bit is latched; i.e., it will remain 0 even if the lamp-out condition goes away. When STATUS1 = 0, the lamp is forced off. STA- TUS0 reports 1 as long as no overcurrent conditions are detected. If an overcurrent condition is detected in any given DPWM period, STATUS0 is cleared for the duration of the following DPWM period. If an overcur- rent condition is not detected in any given DPWM peri- od, STATUS0 is set for the duration of the following dig- ital DPWM period. Forcing the CCFL lamp off by entering shutdown, writing to the mode register, or by toggling SH/SUS sets STATUS1. ID Registers The ID registers return information on the manufacturer, the chip ID, and the chip revision number. The MAX1739 is the first-generation advanced CCFL con- troller, and its ChipRev is 0x00. Reading from the MfgID register returns 0x4D, which is the ASCII code for “M” (for Maxim); the ChipID register returns 0x96. Writing to these registers has no effect. BIT NAME POR STATE DESCRIPTION 2 SHMD2 0 SHMD2 = 1 forces the lamp off and sets STATUS1. SHMD2 = 0 allows the lamp to operate, though it may still be shut down by the SH/SUS pin (depending on the state of SHMD1 and SHMD0). 1 SHMD1 0 When SH /SUS = 0, this bit has no effect. SH/SUS = 1 and SHMD1 = 1 forces the lamp off and sets STATUS1. SH /SUS = 1 and SHMD1 = 0 allow the lamp to operate, though it may still be shut down by the SHMD2 bit. 0 SHMD0 1 When SH /SUS = 1, this bit has no effect. SH /SUS = 0 and SHMD0 = 1 forces the lamp off and sets STATUS1. SH /SUS = 0 and SHMD0 = 0 allows the lamp to operate, though it may still be shut down by the SHMD2 bit. Table 7. SHMD Register Bit Descriptions SH/SUS SHMD2 SHMD1 SHMD0 OPERATING MODE 0 0 X 0 Operate 0 0 X 1 Shutdown, STATUS1 set 1 0 0 X Operate 1 0 1 X Shutdown, STATUS1 set X 1 X X Shutdown, STATUS1 set Table 8. SH/SUS and SHMD Register Truth Table BIT NAME POR STATE DESCRIPTION 1 STATUS1 1 STATUS1 = 0 means that a lamp-out condition has been detected. The STATUS1 bit stays clear even after the lamp-out condition has gone away. The only way to set STATUS1 is to shut off the lamp by programming the mode register or by toggling SH/SUS. 0 STATUS0 1 STATUS0 = 0 means that an overcurrent condition was detected during the previous digital PWM period. STATUS0 = 1 means that no overcurrent condition was detected during the previous digital PWM period. Table 9. Status Register Bit Descriptions (Read Only/Writes Have No Effect) X = Don’t care |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |