| 数据搜索系统,热门电子元器件搜索 |
|
CS5490 数据表(PDF) 18 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5490 数据表(HTML) 18 Page - Cirrus Logic |
|
18 / 57 page ![]() CS5490 18 DS982F3 5. FUNCTIONAL DESCRIPTION 5.1 Power-on Reset (POR) The CS5490 has an internal power supply supervisor circuit that monitors the VDDA and VDDD power supplies and provides the master reset to the chip. If any of these voltages are in the reset range, the master reset is triggered. Both the analog and the digital supply have their own POR circuit. During power-up, both supplies have to be above the rising threshold for the master reset to be de-asserted. Each POR is divided into 2 blocks: rough and fine. Rough POR triggers the fine POR. Rough POR depends only on the supply voltage. The trip point for the fine POR is dependent on bandgap voltage for precise control. The POR circuit also acts as a brownout detect. The fine POR detects supply drops and asserts the master reset. The rough and fine PORs have hysteresis in their rise and fall thresholds which prevents the reset signal from chattering. The following plot shows the POR outputs for each of the power supplies. The POR_Fine_VDDA and POR_Fine_VDDD signals are AND-ed to form the actual power-on reset signal to the digital circuity. The digital circuitry, in turn, holds the master reset signal for 130ms and then de-asserts the master reset. Figure 8. Power-on Reset Timing Table 1. POR Thresholds 5.2 Power Saving Modes Power Saving modes for CS5490 are accessed through the Host Instruction Commands (see 6.1 Host Commands on page 24). • Standby: Powers down all the ADCs, rough buffer, and the temperature sensor. Standby mode disables the system time calculations. Use the wake-up command to come out of standby mode. • Wake-up: Clears the ADC power-down bits and starts the system time calculations. After any of these commands are completed, the DRDY bit is set in the Status0 register. 5.3 Zero-crossing Detection Zero-crossing detection logic is implemented in CS5490. A low-pass filter can be enabled by setting ZX_LPF bit in register Config2. The low-pass filter has a cut-off frequency of 80Hz. It is used to eliminate any harmonics and to help the zero-crossing detection on the 50Hz or 60Hz fundamental component. The zero-crossing level registers are used to set the minimum threshold over which the channel peak has to exceed in order for the zero-crossing detection logic to function. There are two separate zero-crossing level registers: VZXLEVEL is the threshold for the voltage channels, and IZXLEVEL is the threshold for the current channels. VDDA POR_Rough_VDDA POR_Fine_VDDA VDDD POR_Rough_VDDD POR_Fine_VDDD POR_Fine_VDDA POR_Fine_VDDD Master Reset 130ms Vth1 Vth2 Vth5 Vth6 Vth3 Vth4 Vth7 Vth8 Typical POR Threshold Rising Falling VDDA Rough Vth1 =2.34V Vth6 =2.06V Fine Vth2 =2.77V Vth5 =2.59V VDDD Rough Vth3 =1.20V Vth8 =1.06V Fine Vth4 =1.51V Vth7 =1.42V |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |