| 数据搜索系统,热门电子元器件搜索 |
|
AD7607 数据表(PDF) 23 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7607 数据表(HTML) 23 Page - Analog Devices |
|
23 / 33 page ![]() AD7607 Data Sheet Rev. C | Page 22 of 32 TYPICAL CONNECTION DIAGRAM Figure 39 shows the typical connection diagram for the AD7607. There are four AVCC supply pins on the part, and each of the four pins should be decoupled using a 100 nF capacitor at each supply pin and a 10 µF capacitor at the supply source. The AD7607 can operate with the internal reference or an externally applied reference. In this configuration, the AD7607 is configured to operate with the internal reference. When using a single AD7607 device on the board, the REFIN/REFOUT pin should be decoupled with a 10 µF capacitor. When using an application with multiple AD7607 devices, refer to the Internal/External Reference section. The REFCAPA and REFCAPB pins are shorted together and decoupled with a 10 µF ceramic capacitor. The VDRIVE supply is connected to the same supply as the processor. The VDRIVE voltage controls the voltage value of the output logic signals. For layout, decoupling, and grounding hints, see the Layout Guidelines section. POWER-DOWN MODES Two power-down modes are available on the AD7607: standby mode and shutdown mode. The STBY pin controls whether the AD7607 is in normal mode or in one of the two power- down modes. The power-down mode is selected through the state of the RANGE pin when the STBY pin is low. Table 7 shows the configurations required to choose the desired power-down mode. When the AD7607 is placed in standby mode, current consumption is 8 mA maximum and power-up time is approximately 100 µs because the capacitor on the REFCAPA and REFCAPB pins must charge up. In standby mode, the on-chip reference and regulators remain powered up, and the amplifiers and ADC core are powered down. When the AD7607 is placed in shutdown mode, current consumption is 6 µA maximum and power-up time is approximately 13 ms (external reference mode). In shutdown mode, all circuitry is powered down. When the AD7607 is powered up from shutdown mode, a RESET signal must be applied to the AD7607 after the required power-up time has elapsed. Table 7. Power-Down Mode Selection Power-Down Mode STBY RANGE Standby 0 1 Shutdown 0 0 AVCC AGND VDRIVE + REFIN/REFOUT DB0 TO DB15 CONVST A, CONVST B CS RD BUSY RESET AD7607 1µF 10µF 100nF DIGITAL SUPPLY VOLTAGE +2.3V TO +5V ANALOG SUPPLY VOLTAGE 5V1 EIGHT ANALOG INPUTS V1 TO V8 PARALLEL INTERFACE 1DECOUPLING SHOWN ON THE AVCC PIN APPLIES TO EACH AVCC PIN (PIN 1, PIN 37, PIN 38, PIN 48). DECOUPLING CAPACITOR CAN BE SHARED BETWEEN AVCC PIN 37 AND PIN 38. 2DECOUPLING SHOWN ON THE REGCAP PIN APPLIES TO EACH REGCAP PIN (PIN 36, PIN 39). REGCAP2 + 10µF REFCAPA REFCAPB OS 2 OS 1 OS 0 OVERSAMPLING 100nF V1 PAR/SER SEL STBY REF SELECT RANGE V2 V3 V4 V5 V6 V7 V8 REFGND V1GND V2GND V3GND V4GND V5GND V6GND V7GND V8GND VDRIVE VDRIVE Figure 39. Typical Connection Diagram |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |