| 数据搜索系统,热门电子元器件搜索 |
|
LTP5901-IPR 数据表(PDF) 13 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTP5901-IPR 数据表(HTML) 13 Page - Linear Technology |
|
13 / 34 page ![]() LTP5901-IPR/LTP5902-IPR 13 59012iprfa For more information www.linear.com/LTP5901-IPR or www.linear.com/LTP5902-IPR Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: ESD (electrostatic discharge) sensitive device. ESD protection devices are used extensively internal to Eterna. However, high electrostatic discharge can damage or degrade the device. Use proper ESD handling precautions. Note 3: Extended storage at high temperature is discouraged, as this negatively affects the data retention of Eterna’s calibration data. See FLASH Data Retention section for details. Note 4: Actual RF range is subject to a number of installation-specific variables including, but not restricted to ambient temperature, relative humidity, presence of active interference sources, line-of-sight obstacles, and near-presence of objects (for example, trees, walls, signage, and so on) that may induce multipath fading. As a result, range varies. Note 5: As specified by IEEE Std. 802.15.4-2006: Wireless Medium Access Control (MAC) and Physical Layer (PHY) specifications for Low- Rate Wireless Personal Area Networks (LR-WPANs) http://standards.ieee. org/findstds/standard/802.15.4-2011.html. Note 6: IEEE Std. 802.15.4-2006 requires transmitters to maintain a frequency tolerance of better than ±40ppm. Note 7: Per pin I/O types are provided in the Pin Functions section. Note 8: VIH maximum voltage input must respect the VSUPPLY maximum voltage specification. Note 9: See the SmartMesh IP Manager API Guide for the time indication notification definition. Note 10: Network time accuracy is a statistical measure and varies over the temperature range, reporting rate and the location of the device relative to the manager in the network. See Typical Performance Characteristics section for a more detailed description. Note 11: Code execution from flash banks being written or erased is suspended until completion of the flash operation. Note 12: Guaranteed by design. Not production tested. exTernal bus ac characTerisTics The l denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C and VSUPPLY = 3.6V unless otherwise noted. (Note 12) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |