| 数据搜索系统,热门电子元器件搜索 |
|
CS7666 数据表(PDF) 17 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS7666 数据表(HTML) 17 Page - Cirrus Logic |
|
17 / 42 page ![]() CS7666 DS302PP1 17 HIGH for READ packets. The master can read and write to non-existent registers within the selected device. WRITE operations will have no effect; READ operations will return a value of 00h. Station Address Each device on the I 2C bus has a unique 7-bit ad- dress. An eighth bit, the R/W bit, determines if the current data transfer writes data to the slave device or reads data from the slave device. It is common to represent the station address and R/W bit as two 8- bit station addresses, one address for write accesses and another address for read accesses. We will fol- low this practice. The CS7666 default station ad- dress is 34h for writes and 35h for reads. The station address can be changed by writing a new station address to register FFh. The value written to this register does not include the R/W bit. For ex- ample. The default station address (34h write / 35h read) will be stored as 1Ah in register FFh. Write Operations in Three-Byte Mode The WRITE format consists of a three-byte packet. The first byte is the station address with the data di- rection bit set LOW to indicate a write. The second byte is the device register address (0..255). The third byte is the register data (0..255). No addition- al bytes are allowed. Address Set Operation The ADDRESS SET format consists of a two-byte packet which sets the address of a subsequent READ operation. The first byte of the Station Ad- dress with the LSB (data direction bit) set LOW to indicate a write operation. The second byte is the register address (0..255). The ADDRESS SET for- mat is the same as the WRITE format, without the register data (third byte). Read Operations in Three-Byte Mode The READ operation may consist of two or more bytes. The first byte is the station address with the LSB (data direction bit) set HIGH indicating a read operation. The addressed device then sends one or more bytes back from the register last addressed by the previous WRITE operation or the previous AD- DRESS SET operation. Operating CS7666 in Four-Byte I2C Config- uration In this configuration the external controller talks only to the CS7666 through the primary I 2C inter- face. All the other slave devices on the camera External EPROM CS7615 CS7666 controller CS4954 Figure 7. I2C configuration showing primary and secondary I2C busses. To other sub-systems Byte Sequence WRITE Format Packet Detail First Byte Station Address with LSB Set LOW Second Byte Device Register Address (0..255) Third Byte Register Data (0..255) Table 8. WRITE Format Packet Byte Sequence ADDRESS SET format Packet Details First Byte Station Address with LSB Set LOW Second Byte Device Register Address (0..255) Table 9. ADDRESS SET Format Packet Operation Byte Sequence READ Format Packet Details First Byte Station Address with LSB set HIGH; Source Device then Returns One Byte of Register Data (0..255) Second Byte Returned data from CS7666 Table 10. READ Format Packet. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |