14 / 22 page ![]() • NORMAL mode: In this mode, the device performs measurements, calculations, protections, and data updates every 250-ms intervals. Between these intervals, the device is operating in a reduced power stage to minimize total average current consumption. • SLEEP mode: In this mode, the device performs measurements, calculations, and data updates in adjustable time intervals. Between these intervals, the device is operating in a reduced power stage to minimize total average current consumption. • DEEP SLEEP mode: In this mode, the current is reduced slightly while current and voltage are still measured periodically, with a user-defined time between reads. • HIBERNATE mode: In this mode, the device is completely disabled with CE remaining high. This mode is exited upon two valid communications within a specified time window. • OFF mode: The device is completely disabled by pulling CE low. CE disables the internal voltage rail. All non- volatile memory is unprotected. 8.4.1 Lifetime Logging Features The device supports data logging of several key parameters for warranty and analysis: • Maximum and minimum cell temperature • Maximum current in CHARGE or DISCHARGE mode • Maximum and minimum cell voltages • Total run time (This data is stored with a resolution of two hours.) • Time spent different temperature ranges (This data is stored with a resolution of two hours.) 8.4.2 Configuration The device supports accurate data measurements and data logging of several key parameters. 8.4.2.1 Coulomb Counting The device uses an integrating delta-sigma analog-to-digital converter (ADC) for current measurement. The ADC measures charge/discharge flow of the battery by measuring the voltage across a very small external sense resistor. The integrating ADC measures a bipolar signal from a range of –100 mV to 100 mV, with a positive value when V(SRP) – V(SRN), indicating charge current and a negative value indicating discharge current. The current measurement is performed by measuring the voltage drop across the external sense resistor, which can be as low as 1 mΩ, and the polarity of the differential voltage determines if the cell is in the CHARGE or DISCHARGE mode. 8.4.2.2 Cell Voltage Measurements The BQ27Z561-R2 gas gauge measures the cell voltage at 1-s intervals using the ADC. This measured value is internally scaled for the ADC and is calibrated to reduce any errors due to offsets. This data is also used for calculating the impedance of the cell for Impedance Track gas gauging. 8.4.2.3 Auto Calibration The auto-calibration feature helps to cancel any voltage offset across the SRP and SRN pins for accurate measurement of the cell voltage, charge/discharge current, and thermistor temperature. The auto-calibration is performed when there is no communication activity for a minimum of 5 s on the bus lines. 8.4.2.4 Temperature Measurements This device has an internal sensor for on-die temperature measurements, and the ability to support an external temperature measurement via the external NTC on the TS pin. These two measurements are individually enabled and configured. BQ27Z561-R2 SLUSE22 – SEPTEMBER 2020 www.ti.com 14 Submit Document Feedback Copyright © 2020 Texas Instruments Incorporated Product Folder Links: BQ27Z561-R2 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |