16 / 22 page ![]() Design Parameter Example Device Chemistry li-ion Design Voltage 4000 mV Cell Low Voltage 2500 mV 9.2.2 Detailed Design Procedure 9.2.2.1 Changing Design Parameters For the firmware settings needed for the design requirements, refer to the BQ27Z561-R2 Technical Reference Manual (SLUUC54). • To change design capacity, set the data flash value (in mAh) in the Gas Gauging: Design: Design Capacity register. • To set device chemistry, go to the data flash I2C Configuration: Data: Device Chemistry. The BQSTUDIO software automatically populates the correct chemistry identification. This selection is derived from using the BQCHEM feature in the tools and choosing the option that matches the device chemistry from the list. • To set the design voltage, go to Gas Gauging: Design: Design Voltage register. • To set the Cell Low Voltage or clear the Cell Low Voltage, use Settings: Configuration: Init Voltage Low Set or Clear. This is used to set the cell voltage level that will set (clear) the [VOLT_LO] bit in the Interrupt Status register. • To enable the internal temperature and the external temperature sensors: Set Settings:Configuration: Temperature Enable: Bit 0 (TSInt) = 1 for the internal sensor; set Bit 1 (TS1) = 1 for the external sensor. 9.2.3 Calibration Process The calibration of current, voltage, and temperature readings is accessible by writing 0xF081 or 0xF082 to ManufacturerAccess(). A detailed procedure is included in the BQ27Z561-R2 Technical Reference Manual (SLUUC54) in the Calibration section. The description allows for calibration of cell voltage measurement offset, battery voltage, current calibration, coulomb counter offset, PCB offset, CC gain/capacity gain, and temperature measurement for both internal and external sensors. 9.2.4 Gauging Data Updates When a battery pack enabled with the BQ27Z561-R2 gas gauge is cycled, the value of FullChargeCapacity() updates several times, including the onset of charge or discharge, charge termination, temperature delta, resistance updates during discharge, and relaxation. Figure 9-2 shows actual battery voltage, load current, and FullChargeCapacity() when some of those updates occur during a single application cycle. Update points from the plot include: • Charge termination at 7900 s • Relaxation at 9900 s • Resistance update at 11500 s BQ27Z561-R2 SLUSE22 – SEPTEMBER 2020 www.ti.com 16 Submit Document Feedback Copyright © 2020 Texas Instruments Incorporated Product Folder Links: BQ27Z561-R2 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |