| 数据搜索系统,热门电子元器件搜索 |
|
ADE7932 数据表(PDF) 16 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7932 数据表(HTML) 16 Page - Analog Devices |
|
16 / 125 page ![]() ADE7978/ADE7933/ADE7932/ADE7923 Data Sheet Rev. D | Page 16 of 125 Insulation and Safety Related Specifications Table 8. Critical Safety Related Dimensions and Material Properties Parameter Symbol Value Unit Test Conditions/Comments Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration Minimum External Air Gap (Clearance) L(I01) 8.3 mm Measured from input terminals to output terminals, shortest distance through air along the PCB mounting plane, as an aid to PCB layout Minimum External Tracking (Creepage) L(I02) 8.3 mm Measured from input terminals to output terminals, shortest distance path along body Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation Tracking Resistance (Comparative Tracking Index) CTI 400 V IEC 60112 Isolation Group II Material Group DIN VDE 0110, 1/89, Table 1 DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 Insulation Characteristics The ADE7933/ADE7932 are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by the protective circuits. Table 9. Description Test Conditions/Comments Symbol Characteristic Unit Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms I to IV For Rated Mains Voltage ≤ 300 V rms I to IV For Rated Mains Voltage ≤ 400 V rms I to III Climatic Classification 40/085/21 Pollution Degree per DIN VDE 0110, Table 1 2 Maximum Working Insulation Voltage V IORM 846 V peak Input-to-Output Test Voltage, Method b1 V IORM × 1.875 = Vpd(m), 100% production test, t ini = tm = 1 sec, partial discharge < 5 pC V pd(m) 1592 V peak Input-to-Output Test Voltage, Method a V pd(m) After Environmental Tests Subgroup 1 V IORM × 1.5 = Vpd(m), tini = 60 sec, tm = 10 sec, partial discharge < 5 pC 1273 V peak After Input and/or Safety Tests Subgroup 2 and Subgroup 3 V IORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec, partial discharge < 5 pC 1018 V peak Highest Allowable Overvoltage V IOTM 6000 V peak Surge Isolation Voltage V PEAK = 10 kV, 1.2 µs rise time, 50 µs, 50% fall time V IOSM 6250 V peak Safety Limiting Values Maximum value allowed in the event of a failure (see Figure 10) Maximum Junction Temperature T S 150 °C Total Power Dissipation at 25°C P S 2.78 W Insulation Resistance at T S V IO = 500 V R S >109 Ω AMBIENT TEMPERATURE (°C) 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 0 50 100 150 200 Figure 10. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN EN 60747-5-2 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |