3 / 22 page ![]() www.sensirion.com Version 1.1 – April 2021 3/22 1 Sensor Performance 1.1 CO2 Sensing Performance Default conditions of 25 °C, 50 % RH, ambient pressure 1013 mbar, default periodic measurement and 3.3 V supply voltage apply to values in the table below, unless otherwise stated. Parameter Conditions Value CO2 output range1 - 0 – 40’000 ppm SCD40 CO2 measurement accuracy2 400 ppm – 2’000 ppm ± (50 ppm + 5% of reading) SCD41 CO2 measurement accuracy2 400 ppm – 5’000 ppm ± (40 ppm + 5% of reading) Repeatability Typical ± 10 ppm Response time3 τ63%, typical 60 s Accuracy drift per year with automatic self- calibration algorithm enabled4 Typical ± (5 ppm + 0.5 % of reading) Table 1: SCD40 and SCD41 CO2 sensor specifications 1.2 Humidity Sensing Performance5 Parameter Conditions Value Humidity measurement range - 0 %RH – 100 %RH Accuracy (typ.) 15 °C – 35 °C, 20 %RH – 65 %RH ± 6 % RH -10 °C – 60 °C, 0 %RH – 100 %RH ± 9 % RH Repeatability Typical ± 0.4 %RH Response time3 τ63%, typical 90 s Accuracy drift - < 0.25 %RH / year Table 2: SCD4x humidity sensor specifications 1.3 Temperature Sensing Performance5 Parameter Conditions Value Temperature measurement range - - 10°C – 60°C Accuracy (typ.) 15 °C – 35 °C ± 0.8 °C -10 °C – 60 °C ± 1.5 °C Repeatability - ± 0.1°C Response time3 τ63%, typical 120 s Accuracy drift - < 0.03 °C / year Table 3: SCD4x temperature sensor specifications 1 Exposure to CO2 concentrations smaller than 400 ppm can affect the accuracy of the sensor if the automatic self-calibration (ASC) is on. 2 Deviation to a high-precision reference. Accuracy is fulfilled by > 90% of the sensors after calibration. Rough handling, shipping and soldering reduces the accuracy of the sensor. Accuracy is restored with FRC or ASC recalibration features. Accuracy is based on tests with gas mixtures having a tolerance of ± 1.5%. 3 Time for achieving 63% of a respective step function when operating the SCD41 Evaluation Kit with default measurement mode. Response time depends on design-in, signal update rate and environment of the sensor in the final application. 4 For proper function of ASC field-calibration algorithm SCD4x has to be exposed to air with CO2 concentration 400 ppm regularly. Maximum accuracy drift per year estimated from stress tests is ± (5 ppm + 2 % of reading). Higher drift values may occur if the sensor is not handled according to its handling instructions. 5 Design-in of the SCD4x in final application, self-heating of the sensor and the environment impacts the accuracy of the RH/T sensor. To realize indicated specifications, the temperature-offset of the SCD4x inside the customer device must be set correctly (see chapter 3.6). Best RH/T accuracy is realized when operating the SCD4x in low power periodic measurement mode. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |