12 / 22 page ![]() www.sensirion.com Version 1.1 – April 2021 12/22 3.6.5 set_ambient_pressure Description: The set_ambient_pressure command can be sent during periodic measurements to enable continuous pressure compensation. Note that setting an ambient pressure using set_ambient_pressure overrides any pressure compensation based on a previously set sensor altitude. Table 17: set_ambient_pressure I2C sequence description Write (hexadecimal) Input parameter: Ambient pressure Response parameter: - Max. command duration [ms] length [bytes] signal conversion length [bytes] signal conversion 0xe000 3 word[0] = ambient P [Pa] / 100 - - 1 Example: set ambient pressure to 98’700 Pa Write 0xe000 0x03db 0x42 (hexadecimal) Command Ambient P = 98’700 Pa CRC of 0x03db 3.7 Field Calibration To realize high initial and long-term accuracy, the SCD4x includes two field calibration features. Forced recalibration (FRC) enables restoring highest accuracy with the assistance of a CO2 reference value immediately. Typically, FRC is applied to compensate for drifts originating from the sensor assembly process or other extensive stresses. Automatic self-calibration (ASC) ensures highest long-term stability of the SCD4x without the need of manual action steps from the user. The automatic self- calibration algorithm assumes that the sensor is exposed to the atmospheric CO2 concentration of 400 ppm at least once per week. 3.7.1 perform_forced_recalibration Description: To successfully conduct an accurate forced recalibration, the following steps need to be carried out: 1. Operate the SCD4x in the operation mode later used in normal sensor operation (periodic measurement, low power periodic measurement or single shot) for > 3 minutes in an environment with homogenous and constant CO2 concentration. 2. Issue stop_periodic_measurement. Wait 500 ms for the stop command to complete. 3. Subsequently issue the perform_forced_recalibration command and optionally read out the FRC correction (i.e. the magnitude of the correction) after waiting for 400 ms for the command to complete. • A return value of 0xffff indicates that the forced recalibration has failed. Note that the sensor will fail to perform a forced recalibration if it was not operated before sending the command. Please make sure that the sensor is operated at the voltage desired for the application when applying the forced recalibration sequence. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |