| 数据搜索系统,热门电子元器件搜索 |
|
LARA-R6401D 数据表(PDF) 12 Page - u-blox AG |
|
|
|||||||||||||||||||||||||||||
LARA-R6401D 数据表(HTML) 12 Page - u-blox AG |
|
12 / 41 page ![]() LARA-R6 series - Data sheet UBX-21004391 - R09 Interfaces Page 12 of 41 C1-Public When LARA-R6 series modules are in power-off mode (switched off, with a voltage at the VCC module supply input within the normal operating range reported in Table 12), they can be switched on by: • Forcing a low level at the PWR_ON input pin, which is normally set high by an internal pull-up, for a valid time period (see section 4.2.9, module switch-on). The PWR_ON line is intended to be driven by open drain, open collector, or contact switch. ☞ It is recommended to provide accessible test point directly connected to the PWR_ON input pin. 2.3.2 Module power-off LARA-R6 series can be properly switched off, with storage of the current parameter settings in the module’s internal non-volatile memory and a clean network detach, in one of these ways: • AT+CPWROFF command (see the AT commands manual [1]). • Forcing a low pulse at the PWR_ON input pin, which is normally set high by an internal pull-up, for a valid time period (see section 4.2.9, module graceful switch-off). The PWR_ON line is intended to be driven by open drain, open collector or contact switch. An faster and safe emergency power-off procedure of LARA-R6 series modules with storage of the current parameter settings and without a clean network detach can be triggered by: • AT+CFUN=10 command (see the AT commands manual [1]). • Toggling the GPIO input pin configured with the fast and safe power-off function (see section 2.8) An abrupt shutdown occurs on LARA-R6 series modules, without storage of the current parameter settings and without a clean network detach, when: • The VCC supply drops below the extended operating range minimum limit • Forcing a low level at the RESET_N input pin, which is normally set high by an internal pull-up, for a valid time period (see 4.2.10, module abrupt emergency switch-off). The RESET_N line is intended to be driven by open drain, open collector or contact switch. An over-temperature or an under-temperature shutdown occurs on LARA-R6 series modules when the temperature measured within the cellular module reaches the dangerous area if the optional Smart Temperature Supervisor feature is enabled and configured by the dedicated AT command. For more details, see 4.2.15 and the +USTS AT command description in the AT commands manual [1]. 2.3.3 Module reset LARA-R6 series modules can be reset (rebooted), with storage of the current parameter settings in the module’s internal non-volatile memory and a clean network detach, by: • AT+CFUN=16 command (see the AT commands manual [1] for description and other options). • Forcing a low level at the RESET_N input pin, which is normally set high by an internal pull-up, for a valid time period (see 4.2.10, module reset / reboot). The RESET_N line is intended to be driven by open drain, open collector or contact switch. 2.4 SIM interface 2.4.1 SIM card / chip interface LARA-R6 series modules include an interface to connect an external SIM card / chip over the VSIM, SIM_IO, SIM_CLK, SIM_RST pins: the high-speed SIM/ME interface is implemented as well as the automatic detection of the required SIM supporting voltage. Both 1.8 V and 3.0 V SIM types are supported (1.8 V and 3.0 V ME). Activation and deactivation with automatic voltage switch from 1.8 V to 3.0 V is implemented, according to ISO-IEC 7816-3 specs. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |